Accounting for Calibration Uncertainties in X-ray Analysis: Effective Areas in Spectral Fitting

arXiv:1102.4610 First posted 2011-02-22 v1 Cited by 38 61 pages double spaced, 8 figures, accepted for publication in ApJ
Cite this paper ×
BibTeX
@misc{lee2011accounting,
  title = {Accounting for Calibration Uncertainties in X-ray Analysis: Effective Areas in Spectral Fitting},
  author = {Hyunsook Lee and Vinay L. Kashyap and David A. van Dyk and Alanna Connors and Jeremy J. Drake and Rima Izem and Xiao-Li Meng and Shandong Min and Taeyoung Park and Pete Ratzlaff and Aneta Siemiginowska and Andreas Zezas},
  year = {2011},
  eprint = {1102.4610},
  archivePrefix = {arXiv},
  primaryClass = {astro-ph.IM},
  url = {https://arxiv.org/abs/1102.4610}
}
APA
Lee, H., Kashyap, V. L., Dyk, D. A. V., Connors, A., Drake, J. J., Izem, R., Meng, X.-L., Min, S., Park, T., Ratzlaff, P., Siemiginowska, A., & Zezas, A. (2011). Accounting for Calibration Uncertainties in X-ray Analysis: Effective Areas in Spectral Fitting [Preprint]. arXiv. https://doi.org/10.48550/arXiv.1102.4610
GB/T 7714
LEE H, KASHYAP VL, DYK DAV, et al. Accounting for Calibration Uncertainties in X-ray Analysis: Effective Areas in Spectral Fitting[EB/OL]. (2011-02-22)[2026-11-29]. https://arxiv.org/abs/1102.4610.

Abstract

While considerable advance has been made to account for statistical uncertainties in astronomical analyses, systematic instrumental uncertainties have been generally ignored. This can be crucial to a proper interpretation of analysis results because instrumental calibration uncertainty is a form of systematic uncertainty. Ignoring it can underestimate error bars and introduce bias into the fitted values of model parameters. Accounting for such uncertainties currently requires extensive case-specific simulations if using existing analysis packages. Here we present general statistical methods that incorporate calibration uncertainties into spectral analysis of high-energy data. We first present a method based on multiple imputation that can be applied with any fitting method, but is necessarily approximate. We then describe a more exact Bayesian approach that works in conjunction with a Markov chain Monte Carlo based fitting. We explore methods for improving computational efficiency, and in particular detail a method of summarizing calibration uncertainties with a principal component analysis of samples of plausible calibration files. This method is implemented using recently codified Chandra effective area uncertainties for low-resolution spectral analysis and is verified using both simulated and actual Chandra data. Our procedure for incorporating effective area uncertainty is easily generalized to other types of calibration uncertainties.