Macroscopic corrosion front computations of sulfate attack in sewer pipes based on a micro-macro reaction-diffusion model
@misc{chalupeck2012macroscopic,
title = {Macroscopic corrosion front computations of sulfate attack in sewer pipes based on a micro-macro reaction-diffusion model},
author = {Vladimír Chalupecký and Tasnim Fatima and Jens Kruschwitz and Adrian Muntean},
year = {2012},
eprint = {1201.6460},
archivePrefix = {arXiv},
primaryClass = {math.NA},
url = {https://arxiv.org/abs/1201.6460}
}
Chalupecký, V., Fatima, T., Kruschwitz, J., & Muntean, A. (2012). Macroscopic corrosion front computations of sulfate attack in sewer pipes based on a micro-macro reaction-diffusion model [Preprint]. arXiv. https://doi.org/10.48550/arXiv.1201.6460
CHALUPECKÝ V, FATIMA T, KRUSCHWITZ J, et al. Macroscopic corrosion front computations of sulfate attack in sewer pipes based on a micro-macro reaction-diffusion model[EB/OL]. (2012-01-31)[2026-11-29]. https://arxiv.org/abs/1201.6460.
Abstract
We consider a two-scale reaction diffusion system able to capture the corrosion of concrete with sulfates. Our aim here is to define and compute two macroscopic corrosion indicators: typical pH drop and gypsum profiles. Mathematically, the system is coupled, endowed with micro-macro transmission conditions, and posed on two different spatially-separated scales: one microscopic (pore scale) and one macroscopic (sewer pipe scale). We use a logarithmic expression to compute values of pH from the volume averaged concentration of sulfuric acid which is obtained by resolving numerically the two-scale system (microscopic equations with direct feedback with the macroscopic diffusion of one of the reactants). Furthermore, we also evaluate the content of the main sulfatation reaction (corrosion) product-the gypsum-and point out numerically a persistent kink in gypsum's concentration profile. Finally, we illustrate numerically the position of the free boundary separating corroded from not-yet-corroded regions.