Suppression of the near-infrared OH night sky lines with fibre Bragg gratings - first results
@misc{ellis2012suppression,
title = {Suppression of the near-infrared OH night sky lines with fibre Bragg gratings - first results},
author = {S. C. Ellis and J. Bland-Hawthorn and J. Lawrence and A. J. Horton and C. Trinh and S. G. Leon-Saval and K. Shortridge and J. Bryant and S. Case and M. Colless and W. Couch and K. Freeman and L. Gers and K. Glazebrook and R. Haynes and S. Lee and H.-G. Loehmannsroeben and J. O.Byrne and S. Miziarski and M. Roth and B. Schmidt and C. G. Tinney and J. Zheng},
year = {2012},
eprint = {1206.6551},
archivePrefix = {arXiv},
primaryClass = {astro-ph.IM},
url = {https://arxiv.org/abs/1206.6551}
}
Ellis, S. C., Bland-Hawthorn, J., Lawrence, J., Horton, A. J., Trinh, C., Leon-Saval, S. G., Shortridge, K., Bryant, J., Case, S., Colless, M., Couch, W., Freeman, K., Gers, L., Glazebrook, K., Haynes, R., Lee, S., Loehmannsroeben, H.-G., O.Byrne, J., Miziarski, S., & … Zheng, J. (2012). Suppression of the near-infrared OH night sky lines with fibre Bragg gratings - first results [Preprint]. arXiv. https://doi.org/10.48550/arXiv.1206.6551
ELLIS SC, BLAND-HAWTHORN J, LAWRENCE J, et al. Suppression of the near-infrared OH night sky lines with fibre Bragg gratings - first results[EB/OL]. (2012-06-28)[2026-11-29]. https://arxiv.org/abs/1206.6551.
Abstract
The background noise between 1 and 1.8 microns in ground-based instruments is dominated by atmospheric emission from hydroxyl molecules. We have built and commissioned a new instrument, GNOSIS, which suppresses 103 OH doublets between 1.47 - 1.7 microns by a factor of 1000 with a resolving power of 10,000. We present the first results from the commissioning of GNOSIS using the IRIS2 spectrograph at the AAT. The combined throughput of the GNOSIS fore-optics, grating unit and relay optics is 36 per cent, but this could be improved to 46 per cent with a more optimal design. We measure strong suppression of the OH lines, confirming that OH suppression with fibre Bragg gratings will be a powerful technology for low resolution spectroscopy. The integrated OH suppressed background between 1.5 and 1.7 microns is reduced by a factor of 9 compared to a control spectrum using the same system without suppression. The potential of low resolution OH suppressed spectroscopy is illustrated with example observations. The GNOSIS background is dominated by detector dark current below 1.67 microns and by thermal emission above 1.67 microns. After subtracting these we detect an unidentified residual interline component of 860 +/ 210 ph/s/m^2/micron/arcsec^2. This component is equally bright in the suppressed and control spectra. We have investigated the possible source of the interline component, but were unable to discriminate between a possible instrumental artifact and intrinsic atmospheric emission. Resolving the source of this emission is crucial for the design of fully optimised OH suppression spectrographs. The next generation OH suppression spectrograph will be focussed on resolving the source of the interline component, taking advantage of better optimisation for a FBG feed. We quantify the necessary improvements for an optimal OH suppressing fibre spectrograph design.