Proton radiography to improve proton radiotherapy: Simulation study at different proton beam energies

arXiv:1601.08074 First posted 2016-01-29 v1 Cited by 2 6 pages, 6 figures, Presented at Jagiellonian Symposium on Fundamental and Applied Subatomic Physics, 7-12 June, 2015, Kraków, Poland
Cite this paper ×
BibTeX
@misc{biegun2016proton,
  title = {Proton radiography to improve proton radiotherapy: Simulation study at different proton beam energies},
  author = {A.K. Biegun and Jun Takatsu and M-J. van Goethem and E.R. van der Graaf and M. van Beuzekom and J. Visser and S. Brandenburg},
  year = {2016},
  eprint = {1601.08074},
  archivePrefix = {arXiv},
  primaryClass = {physics.med-ph},
  url = {https://arxiv.org/abs/1601.08074}
}
APA
Biegun, A., Takatsu, J., Goethem, M.-J. V., Graaf, E. V. D., Beuzekom, M. V., Visser, J., & Brandenburg, S. (2016). Proton radiography to improve proton radiotherapy: Simulation study at different proton beam energies [Preprint]. arXiv. https://doi.org/10.48550/arXiv.1601.08074
GB/T 7714
BIEGUN A, TAKATSU J, GOETHEM MJV, et al. Proton radiography to improve proton radiotherapy: Simulation study at different proton beam energies[EB/OL]. (2016-01-29)[2026-11-29]. https://arxiv.org/abs/1601.08074.

Abstract

To improve the quality of cancer treatment with protons, a translation of X-ray Computed Tomography (CT) images into a map of the proton stopping powers needs to be more accurate. Proton stopping powers determined from CT images have systematic uncertainties in the calculated proton range in a patient of typically 3-4% and even up to 10% in region containing bone citeUSchneider1995,USchneider1996,WSchneider2000,GCirrone2007,HPaganetti2012,TPlautz2014,GLandry2013,JSchuemann2014. As a consequence, part of a tumor may receive no dose, or a very high dose can be delivered in healthy ti\-ssues and organs at risks (e.g. brain stem) citeACKnopf2013. A transmission radiograph of high-energy protons measuring proton stopping powers directly will allow to reduce these uncertainties, and thus improve the quality of treatment. The best way to obtain a sufficiently accurate radiograph is by tracking individual protons traversing the phantom (patient) citeGCirrone2007,TPlautz2014,VSipala2013. In our simulations we have used an ideal position sensitive detectors measuring a single proton before and after a phantom, while the residual energy of a proton was detected by a BaF_2 crystal. To obtain transmission radiographs, diffe\-rent phantom materials have been irradiated with a 3x3 cm^2 scattered proton beam, with various beam energies. The simulations were done using the Geant4 simulation package citeSAgostinelli2003. In this study we focus on the simulations of the energy loss radiographs for various proton beam energies that are clinically available in proton radiotherapy.

Post #1 · the paper

Discussion

No comments yet. Start the discussion!