Parasitic neutron beam monitoring: proof of concept on gamma monitoring of neutron chopper phases

arXiv:2004.07336 First posted 2020-04-15 v2 6 pages, 8 figures. Version: accepted Euro Physics Letters
Cite this paper ×
BibTeX
@misc{issa2020parasitic,
  title = {Parasitic neutron beam monitoring: proof of concept on gamma monitoring of neutron chopper phases},
  author = {F. Issa and R. Hall-Wilton and A. Quintanilla and M. Olsson and D. Zielinski and K. Kanaki and N. Tsapatsaris},
  year = {2020},
  eprint = {2004.07336},
  archivePrefix = {arXiv},
  primaryClass = {physics.ins-det},
  url = {https://arxiv.org/abs/2004.07336}
}
APA
Issa, F., Hall-Wilton, R., Quintanilla, A., Olsson, M., Zielinski, D., Kanaki, K., & Tsapatsaris, N. (2020). Parasitic neutron beam monitoring: proof of concept on gamma monitoring of neutron chopper phases [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2004.07336
GB/T 7714
ISSA F, HALL-WILTON R, QUINTANILLA A, et al. Parasitic neutron beam monitoring: proof of concept on gamma monitoring of neutron chopper phases[EB/OL]. (2020-04-15)[2026-11-29]. https://arxiv.org/abs/2004.07336.

Abstract

Neutron beam monitors are an essential diagnostic component of neutron scattering facilities. They are used to measure neutron flux, calibrating experiments performed on the instruments, allowing measurement of facility performance, understanding of the effect on the neutrons of beam-line components (such as choppers), calibration of detectors and tracking of beam stability. Ideally beam monitors should not perturb the beam. Previous work shows commercial beam monitors attenuate the beam by a few percent in the worst case due to the 1-2 mm thick Aluminium entrance and exit windows and the material inside. Parasitic methods of neutron beam diagnostics, where there is no beam monitor directly in the beam, would be preferable. This paper presents the concept of a parasitic method of monitoring the beam which can be used for neutron chopper phasing. This is achieved by placing a gamma detector close to a rotating chopper and measures a signal proportional to the flux absorbed by the chopper. Neutrons interact with the Boron absorber on the chopper disc lead to gamma emission at 480 keV. Detection of these gamma rays is used to determine the chopper phasing and timing. Potentially information on the flux of the beamline can be extracted. Results from a proof of concept implementation show that diagnosis of neutron chopper phases is feasible.

Post #1 · the paper

Discussion

No comments yet. Start the discussion!