Synchrotron Microtomography and Neutron Radiography Characterization of the Microstruture and Water Absorption of Concrete from Pompeii

arXiv:2005.13114 First posted 2020-05-27 v2
Cite this paper ×
BibTeX
@misc{xu2020synchrotron,
  title = {Synchrotron Microtomography and Neutron Radiography Characterization of the Microstruture and Water Absorption of Concrete from Pompeii},
  author = {Ke Xu and Anton S. Tremsin and Jiaqi Li and Daniela M. Ushizima and Catherine A. Davy and Amine Bouterf and Ying Tsun Su and Milena Marroccoli and Anna Maria Mauro and Massimo Osanna and Antonio Telesca and Paulo J. M. Monteiro},
  year = {2020},
  eprint = {2005.13114},
  archivePrefix = {arXiv},
  primaryClass = {physics.app-ph},
  url = {https://arxiv.org/abs/2005.13114}
}
APA
Xu, K., Tremsin, A. S., Li, J., Ushizima, D. M., Davy, C. A., Bouterf, A., Su, Y. T., Marroccoli, M., Mauro, A. M., Osanna, M., Telesca, A., & Monteiro, P. J. M. (2020). Synchrotron Microtomography and Neutron Radiography Characterization of the Microstruture and Water Absorption of Concrete from Pompeii [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2005.13114
GB/T 7714
XU K, TREMSIN AS, LI J, et al. Synchrotron Microtomography and Neutron Radiography Characterization of the Microstruture and Water Absorption of Concrete from Pompeii[EB/OL]. (2020-05-27)[2026-11-29]. https://arxiv.org/abs/2005.13114.

Abstract

There is renewed interest in using advanced techniques to characterize ancient Roman concrete. In the present work, samples were drilled from the "Hospitium" in Pompeii and were analyzed by synchrotron microtomography (uCT) and neutron radiography to study how the microstructure, including the presence of induced cracks, affects their water adsorption. The water distribution and absorptivity were quantified by neutron radiography. The 3D crack propagation, pore size distribution and orientation, tortuosity, and connectivity were analyzed from uCT results using advanced imaging methods. The concrete characterization also included classical methods (e.g., differential thermal-thermogravimetric, X-ray diffractometry, and scanning electron microscopy). Ductile fracture patterns were observed once cracks were introduced. When compared to Portland cement mortar/concrete, Pompeii samples had relatively high porosity, low connectivity, and similar coefficient of capillary penetration. In addition, the permeability was predicted from models based on percolation theory and the pore structure data to evaluate the fluid transport properties.

Post #1 · the paper

Discussion

No comments yet. Start the discussion!