High-sensitivity mapping of magnetic induction fields with nanometer-scale resolution: comparison of off-axis electron holography and pixelated differential phase contrast

arXiv:2008.09308 First posted 2020-08-21 v2
Cite this paper ×
BibTeX
@misc{boureau2020highsensitivity,
  title = {High-sensitivity mapping of magnetic induction fields with nanometer-scale resolution: comparison of off-axis electron holography and pixelated differential phase contrast},
  author = {Victor Boureau and Michal Staňo and Jean-Luc Rouvière and Jean-Christophe Toussaint and Olivier Fruchart and David Cooper},
  year = {2020},
  eprint = {2008.09308},
  archivePrefix = {arXiv},
  primaryClass = {physics.app-ph},
  url = {https://arxiv.org/abs/2008.09308}
}
APA
Boureau, V., Staňo, M., Rouvière, J.-L., Toussaint, J.-C., Fruchart, O., & Cooper, D. (2020). High-sensitivity mapping of magnetic induction fields with nanometer-scale resolution: comparison of off-axis electron holography and pixelated differential phase contrast [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2008.09308
GB/T 7714
BOUREAU V, STAŇO M, ROUVIÈRE JL, et al. High-sensitivity mapping of magnetic induction fields with nanometer-scale resolution: comparison of off-axis electron holography and pixelated differential phase contrast[EB/OL]. (2020-08-21)[2026-11-29]. https://arxiv.org/abs/2008.09308.

Abstract

We compare two transmission electron microscopy (TEM) based techniques that can provide highly spatially resolved quantitative measurements of magnetic induction fields at high sensitivity. To this end, the magnetic induction of a ferromagnetic NiFe nanowire has been measured and compared to micromagnetic modelling. State-of-the-art electron holography has been performed using the averaging of large series of holograms to improve the sensitivity of the measurements. These results are then compared those obtained from pixelated (or 4D) scanning transmission electron microscopy (STEM). This emerging technique uses a pixelated detector to image the local diffraction patterns as the beam is scanned over the sample. For each diffraction pattern, the deflection of the beam is measured and converted into magnetic induction, while scanning the beam allows to build a map. Aberration corrected Lorentz (field-free) configurations of the TEM and STEM were used for an improved spatial resolution. We show that the pixelated STEM approach, even when performed using an old generation of charge-coupled device camera, provides better sensitivity at the expense of spatial resolution. A more general comparison of the two techniques is given.