A global phase fitting approach for the analysis of ^129Xe electric dipole moment measurements

arXiv:2103.16221 First posted 2021-03-30 v1 This writeup aims for providing supplemental information for interested readers of the paper published at arXiv:2008.07975. This writeup is a translated excerpt of the author's doctoral thesis in Chinese entitled "Research on realization and application of textmu T-level magnetic fields of high homogeneity inside magnetically shielded rooms", which is not available yet
Cite this paper ×
BibTeX
@misc{liu2021a,
  title = {A global phase fitting approach for the analysis of ^129Xe electric dipole moment measurements},
  author = {Tianhao Liu},
  year = {2021},
  eprint = {2103.16221},
  archivePrefix = {arXiv},
  primaryClass = {physics.atom-ph},
  url = {https://arxiv.org/abs/2103.16221}
}
APA
Liu, T. (2021). A global phase fitting approach for the analysis of ^129Xe electric dipole moment measurements [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2103.16221
GB/T 7714
LIU T. A global phase fitting approach for the analysis of ^129Xe electric dipole moment measurements[EB/OL]. (2021-03-30)[2026-11-29]. https://arxiv.org/abs/2103.16221.

Abstract

Measuring the size of permanent electric dipole moments (EDM) of a particle or system provides a powerful tool to test Beyond-the-Standard-Model physics. The diamagnetic ^129Xe atom is one of the promising candidates for EDM experiments due to its obtainable high nuclear polarization and its long spin-coherence time in a homogeneous magnetic field. By measuring the spin precession frequencies of polarized ^129Xe and ^3He, a new upper limit on the ^129Xe atomic EDM d_A(^129Xe) was reported in Phys. Rev. Lett. 123, 143003 (2019). This writeup proposes a new evaluation method based on global phase fitting (GPF) for analyzing the continuous phase development of the ^3He-^129Xe comagnetometer signal. The Cramer-Rao Lower Bound on the ^129Xe EDM for the GPF method is theoretically derived and shows the benefit of achieving high statistical sensitivity without bringing new systematic uncertainties. The robustness of the GPF method is verified with Monte-Carlo studies. By optimizing the analysis parameters and adding few more data that could not be analyzed with the former method, a result of d_A (^129Xe)=(1.1 +/- 3.6_(stat) +/- 2.0_(syst))x 10 ^-28 e cm, is obtained and is used to derive the upper limit of ^129Xe permanent EDM at 95% C.L. |d_textA(^129textXe)| < 8.3 x 10^-28 e cm. This limit is a factor of 1.7 smaller as compared to the previous result.

Post #1 · the paper

Discussion

No comments yet. Start the discussion!