STAR-XPC: Set Transformer for Estimating X-ray Transmission in Polymer Composites

arXiv:2610.28709 First posted 2026-10-20 v2 13 pages, 6 figures
Cite this paper ×
BibTeX
@misc{erer2026starxpc,
  title = {STAR-XPC: Set Transformer for Estimating X-ray Transmission in Polymer Composites},
  author = {Can Erer and H. Birkan Yilmaz and Nebahat Aral},
  year = {2026},
  eprint = {2610.28709},
  archivePrefix = {arXiv},
  primaryClass = {cs.LG},
  url = {https://arxiv.org/abs/2610.28709}
}
APA
Erer, C., Yilmaz, H. B., & Aral, N. (2026). STAR-XPC: Set Transformer for Estimating X-ray Transmission in Polymer Composites [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2610.28709
GB/T 7714
ERER C, YILMAZ HB, ARAL N. STAR-XPC: Set Transformer for Estimating X-ray Transmission in Polymer Composites[EB/OL]. (2026-10-20)[2026-11-29]. https://arxiv.org/abs/2610.28709.

Abstract

Evaluating the energy transmission ratio of an X-ray beam through a polymer composite is a challenging task in radiation shielding studies. The reference solution with Monte Carlo transport simulation is highly accurate but computationally expensive: each of our reference simulations is capped at 4x10^9 photon histories and a 20,000 s (over 5 hours) time limit, while closed-form analytical methods fail to represent such complex scenarios. We present an artificial neural network model that maps the unordered multi-set of molecular constituents, their mass fractions, and four bulk physical descriptors directly to the transmission ratio I(t)/I_0 in 1-3 milliseconds. The model is a Set Transformer, which makes it permutation invariant by construction and accepts mixtures of different sizes up to 11 constituents within a fixed-size padded set. Each constituent is embedded with a chemistry-pretrained transformer language model, ChemBERTa. In our proposed method, training data are produced by an automated PENELOPE/penEasy pipeline using the radiation source at 30, 80, 100, and 120 kV tube voltages over polyethylene-based shielding composite slabs of thicknesses spanning 0.15-2.5 mm. After preprocessing, the dataset contains n = 4697 simulated configurations on which a leakage-free, jointly stratified 10-fold cross-validation is performed, attaining mean squared error MSE = (1.12 +/- 0.56)x10^-4, normalized-MSE percentage NMSE% = 0.0294% +/- 0.0147%, and R^2 = 0.9988. The corresponding per-sample percentage errors give an alpha-trimmed (alpha = 0.10) absolute percentage error (APE) of 1.66% and a median APE of 1.15%. Our model's inference is several orders of magnitude faster than the underlying Monte Carlo simulation (sub-millisecond per query vs. several hours for the reference run) with effective accuracy in predicting I(t)/I_0.

Post #1 · the paper

Discussion