Adaptive Reliability Reserves for Residential Battery Fleets

arXiv:2611.34779 First posted 2026-11-25 v1 22 pages, 5 figures; code and artifacts: https://github.com/MaruthiV/homefleet
Cite this paper ×
BibTeX
@misc{vemula2026adaptive,
  title = {Adaptive Reliability Reserves for Residential Battery Fleets},
  author = {Maruthi Vemula and Neeraj Praneeth Gajula},
  year = {2026},
  eprint = {2611.34779},
  archivePrefix = {arXiv},
  primaryClass = {cs.LG},
  url = {https://arxiv.org/abs/2611.34779}
}
APA
Vemula, M., & Gajula, N. P. (2026). Adaptive Reliability Reserves for Residential Battery Fleets [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2611.34779
GB/T 7714
VEMULA M, GAJULA NP. Adaptive Reliability Reserves for Residential Battery Fleets[EB/OL]. (2026-11-25)[2026-11-29]. https://arxiv.org/abs/2611.34779.

Abstract

In a Houston 2024 replay, replacing a fixed 20 percent battery reserve with a county-risk threshold raises observed five-hour backup coverage from 75.0 percent to 86.5 percent and adds USD 10.2 in modeled annualized margin per home (paired 95 percent interval: USD +1.7 to USD +21.7). The paired coverage-gain interval includes zero. This is a conditional simulation result, not measured company reliability. Residential batteries face this tradeoff because market discharge consumes energy also needed for household outages. We release HomeFleet-ERCOT, combining observed prices and county outages with identified simulated homes and causal controller inputs. We compare independent-home optimization with 21 proximal policy optimization (PPO) training runs; ten promise-cost candidates span 31.1 percent-96.3 percent backup coverage. Of these, 10 have lower modeled margin than fixed 20 percent, and 3 also have lower coverage. Chronological, geographic, fleet, and storm tests examine transfer. An alert charging override has a conditional energy-and-power sufficiency guarantee, but only 19.5 percent of 41 county mass-outage episodes provide enough continuous warning for every battery preset. Synthetic tests include short, missed, and false warnings, load uplift, capacity loss, and dropout. A static AC audit retains existing feeder violations; aging comparisons expose model sensitivity. The released benchmark, controllers, and checkpoints provide a reproducible basis for comparing these tradeoffs. This work supports the design of residential battery programs that assess market value and household backup service together.

Post #1 · the paper

Discussion

No comments yet. Start the discussion!