Gamma radiation measurements and dose rates in commercially-used natural tiling rocks (granites)

arXiv:physics/0212104 First posted 2002-12-28 v2 Cited by 203 22 pages including 2 tables and 4 figures; improved text including new references. To appear in Journ. of Env. Radioactivity
Cite this paper ×
BibTeX
@misc{tzortzis2002gamma,
  title = {Gamma radiation measurements and dose rates in commercially-used natural tiling rocks (granites)},
  author = {M. Tzortzis and H. Tsertos (Dept. of Physics and Univ. of Cyprus) and S. Christofides and G. Christodoulides (Medical Phys. Dept. and Nicosia General Hospital)},
  year = {2002},
  eprint = {physics/0212104},
  archivePrefix = {arXiv},
  primaryClass = {physics.med-ph},
  url = {https://arxiv.org/abs/physics/0212104}
}
APA
Tzortzis, M., Physics, H. T. (. O., Cyprus), U. O., Christofides, S., Dept., G. C. (. P., & Hospital), N. G. (2002). Gamma radiation measurements and dose rates in commercially-used natural tiling rocks (granites) [Preprint]. arXiv. https://doi.org/10.48550/arXiv.physics/0212104
GB/T 7714
TZORTZIS M, PHYSICS HT(O, CYPRUS) UO, et al. Gamma radiation measurements and dose rates in commercially-used natural tiling rocks (granites)[EB/OL]. (2002-12-28)[2026-11-29]. https://arxiv.org/abs/physics/0212104.

Abstract

The gamma radiation in samples of a variety of natural tiling rocks (granites) imported in Cyprus for use in the building industry was measured, employing high-resolution gamma-ray spectroscopy. The rock samples were pulverized, sealed in 1 litre plastic Marinelli beakers, and measured in the laboratory with an accumulating time between 10 and 14 hours each. From the measured gamma-ray spectra, activity concentrations were determined for Th-232 (range from 1 to 906 Bq/kg), U-238 (from 1 to 588 Bq/kg) and K-40 (from 50 to 1606 Bq/kg). The total absorbed dose rates in air calculated from the concentrations of the three radionuclides, Th-232 and U-238 series and K-40, ranged from 7 to 1209 nGy/h for full utilization of the materials, from 4 to 605 nGy/h for half utilization and from 2 to 302 nGy/h for one quarter utilization. The total effective dose rates per person indoors were determined to be between 0.02 to 2.97 mSv/y for half utilization of the materials. Applying dose criteria recently recommended by the EU for superficial materials, 25 of the samples meet the exemption dose limit of 0.3 mSv/y, two of them meet the upper dose limit of 1 mSv/y and only one exceeds clearly this limit.

Post #1 · the paper

Discussion

No comments yet. Start the discussion!