Mejora de la sensibilidad de banda ancha mediante retroalimentación cuántica coherente con simetría PT
Broadband sensitivity improvement via coherent quantum feedback with PT symmetry
Broadband sensitivity improvement via coherent quantum feedback with PT symmetry
@misc{li2020broadband,
title = {Broadband sensitivity improvement via coherent quantum feedback with PT symmetry},
author = {Xiang Li and Maxim Goryachev and Yiqiu Ma and Michael E. Tobar and Chunnong Zhao and Rana X Adhikari and Yanbei Chen},
year = {2020},
eprint = {2012.00836},
archivePrefix = {arXiv},
primaryClass = {quant-ph},
url = {https://arxiv.org/abs/2012.00836}
}
Li, X., Goryachev, M., Ma, Y., Tobar, M. E., Zhao, C., Adhikari, R. X., & Chen, Y. (2020). Broadband sensitivity improvement via coherent quantum feedback with PT symmetry [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2012.00836
LI X, GORYACHEV M, MA Y, et al. Broadband sensitivity improvement via coherent quantum feedback with PT symmetry[EB/OL]. (2020-12-01)[2026-11-29]. https://arxiv.org/abs/2012.00836.
Resumen
Un detector resonante convencional suele estar sujeto a un compromiso entre el ancho de banda y la sensibilidad pico, que se puede rastrear hasta el límite de Cramér-Rao cuántico. Se ha demostrado que la dispersión anómala lo mejora mediante amplificación de señal y es, por tanto, más robusta frente a la decoherencia, aunque conduce a inestabilidades. Proposamos un amplificador cuántico estable aplicable a sistemas lineales que operan en los límites fundamentales de detección, habilitado por la amplificación paramétrica no degenerada de dos modos. En el umbral, uno de los modos del amplificador forma un sistema simétrico PT del modo original del detector. Se muestran mejoras de sensibilidad para detectores de ondas gravitacionales de interferometría láser y detectores de axiones en cavidades de microondas.
A conventional resonant detector is often subject to a trade-off between bandwidth and peak sensitivity that can be traced back to quantum Cramer-Rao Bound. Anomalous dispersion has been shown to improve it by signal amplification and is thus more robust against decoherence, while it leads to instabilities. We propose a stable quantum amplifier applicable to linear systems operating at the fundamental detection limits, enabled by two-mode non-degenerate parametric amplification. At threshold, one mode of the amplifier forms a PT-symmetric system of original detector mode. Sensitivity improvements are shown for laser-interferometric gravitational-wave detectors and microwave cavity axion detectors.