近接、遠隔、どこにいても:ホログラフィックおよびピッチグラフィックな干渉計像の線量効率に関するシミュレーション
Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging
Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging
@misc{du2019near,
title = {Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging},
author = {Ming Du and Doga Gursoy and Chris Jacobsen},
year = {2019},
eprint = {1908.06770},
archivePrefix = {arXiv},
primaryClass = {eess.IV},
url = {https://arxiv.org/abs/1908.06770}
}
Du, M., Gursoy, D., & Jacobsen, C. (2019). Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging [Preprint]. arXiv. https://doi.org/10.48550/arXiv.1908.06770
DU M, GURSOY D, JACOBSEN C. Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging[EB/OL]. (2019-08-16)[2026-11-29]. https://arxiv.org/abs/1908.06770.
要旨
X 線顕微鏡に関する異なる研究では、試料の直後の近傍(フレネル領域)または遠傍(フランクホーファー領域)の強度分布記録を伴う画像化モードの線量効率について矛盾した結論が得られている。ここでは、ptychography が複数の重なる有限サイズの照明位置を関与させる近傍ホログラフィー(NFH)、近傍ptychography(NFP)、および遠傍ptychography(FFP)の線量効率に関する数値研究を報告する。一貫した蛍光量を用いた場合、単一の遠傍回折パターン記録を関与させる一貫した回折画像化(CDI)で報告されているとは異なり、すべての手法が類似した画像品質を提供することがわかった。ただし、遠傍ptychography はわずかに高い空間分解能と低い平均誤差を示した。これらの結果は、実験と画像再構成が適切に行われる場合、試料が近傍であっても遠傍であっても構わないことを支持しており、試料への光子蛍光量は空間分解能の限界を決定するものであることを示唆している。
Different studies in x-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. We present here a numerical study on the dose efficiency of near-field holography (NFH), near-field ptychography (NFP), and far-field ptychography (FFP), where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging (CDI), which involves recording a single far-field diffraction pattern, we find that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near, or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.