長期モニタリングによる臨界域における自己電位シグネチャの定量的理解の進展
Advancing quantitative understanding of self-potential signatures in the critical zone through long-term monitoring
Advancing quantitative understanding of self-potential signatures in the critical zone through long-term monitoring
@misc{hu2020advancing,
title = {Advancing quantitative understanding of self-potential signatures in the critical zone through long-term monitoring},
author = {Kaiyan Hu and Damien Jougnot and Qinghua Huang and Majken C. Looms and Niklas Linde},
year = {2020},
eprint = {2003.08098},
archivePrefix = {arXiv},
primaryClass = {physics.geo-ph},
url = {https://arxiv.org/abs/2003.08098}
}
Hu, K., Jougnot, D., Huang, Q., Looms, M. C., & Linde, N. (2020). Advancing quantitative understanding of self-potential signatures in the critical zone through long-term monitoring [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2003.08098
HU K, JOUGNOT D, HUANG Q, et al. Advancing quantitative understanding of self-potential signatures in the critical zone through long-term monitoring[EB/OL]. (2020-03-18)[2026-11-29]. https://arxiv.org/abs/2003.08098.
要旨
自己電位(SP)法は、不飽和帯における水およびイオンフラックスに関する洞察を提供する可能性がある被動的地物理的手法である。現在、定量的な不飽和帯水文学におけるその定常的な利用を妨げている主要な障壁は、様々な発生源メカニズムから生じる信号の重ね合わせ、電極設計および年齢に依存し予測が困難な電極極化効果、および電極の直近における水飽和度、孔水化学、粘土含有量、および温度である。本稿では、デンマークの HOBE 水文観測所内の不飽和帯において、異なる深さで取得されたデータのうち最初の 4 年間を対象とした独自の長期 SP 監視実験を提示する。最先端の SP 理論を、流れおよび輸送シミュレーションと組み合わせ、観測データを再現し、観測された不一致の理由を提案する。予測は監視開始後最初の 6 ヶ月では概ね満足できるものだったが、その後は観測データの模式および大きさが劇的に変化し始めた。我々の主要な観察結果は、(1) 予測された SP の大きさは有効な過剰電荷が水飽和度とどのようにスケールするかに対して強く敏感であり、不飽和条件下における電気動力学現象のより正確なモデル構築のために継続的な研究が必要であるという点、(2) 最も浅い電極において 1 年の時間スケールで電極極化に著しい変化が生じ、電極効果は無視できないため、将来の監視研究では明示的な電極モデルの検討が必要であるという点、(3) 塩分および孔水電導度のより良い予測のために、多率質量輸送と反応性輸送モデリングが必要であるという点である。我々は、SP データおよび補完データの時系列を公開することにより、他の研究者がこれらのデータに対して新しい SP モデリングアプローチおよび解釈戦略を検証することを刺激することを希望する。
The self-potential (SP) method is a passive geophysical technique, which may offer insights about water and ionic fluxes in the vadose zone. The main obstacles presently prohibiting its routine use in quantitative vadose zone hydrology are the superposition of signals arising from various source mechanisms, difficult-to-predict electrode polarization effects that depend on electrode design and age, as well as water saturation, pore water chemistry, clay content, and temperature in the immediate vicinity of the electrodes. We present a unique long-term SP monitoring experiment focusing on the first four years of data acquired at different depths in the vadose zone within the HOBE hydrological observatory in Denmark. Using state-of-the-art SP theory combined with flow and transport simulations, we attempt to replicate the observed data and suggest reasons for observed discrepancies. The predictions are overall satisfactory during the first six months of monitoring after which both the patterns and magnitudes of the observed data change drastically. Our main observations are (1) that predicted SP magnitudes are strongly sensitive to how the effective excess charge scales with water saturation implying that continued research is needed to build more accurate models of electrokinetic phenomena in unsaturated conditions, (2) that significant changes in electrode polarization occur in the shallowest electrodes at time scales of a year, suggesting that electrode effects cannot be ignored and that explicit electrode modeling should be considered in future monitoring studies, and (3) that multi-rate mass transfer and reactive transport modeling are needed to better predict salinity and pore water conductivity. We hope to stimulate other researchers to test new SP modeling approaches and interpretation strategies against these data by making the SP and complimentary data time-series available.