量子フィルタ用空腔の最適オフセット
Optimal detuning for quantum filter cavities
Optimal detuning for quantum filter cavities
@misc{whittle2020optimal,
title = {Optimal detuning for quantum filter cavities},
author = {Chris Whittle and Kentaro Komori and Dhruva Ganapathy and Lee McCuller and Lisa Barsotti and Nergis Mavalvala and Matthew Evans},
year = {2020},
eprint = {2008.08086},
archivePrefix = {arXiv},
primaryClass = {astro-ph.IM},
url = {https://arxiv.org/abs/2008.08086}
}
Whittle, C., Komori, K., Ganapathy, D., McCuller, L., Barsotti, L., Mavalvala, N., & Evans, M. (2020). Optimal detuning for quantum filter cavities [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2008.08086
WHITTLE C, KOMORI K, GANAPATHY D, et al. Optimal detuning for quantum filter cavities[EB/OL]. (2020-08-18)[2026-11-29]. https://arxiv.org/abs/2008.08086.
要旨
真空の量子ゆらぎは、有史以来最も感度が高い精密計測装置の一つに位置づけられる重力波干渉計の感度に根本的な限界を課す。従来の圧縮真空の注入は、一方の四角形成分の量子ノイズを低減する代わりに他方の成分のノイズを増大させるというトレードオフを伴う。この手法は、第 3 観測期間(O3)における Advanced LIGO と Advanced Virgo 干渉計の感度向上に寄与したが、将来のアームパワーおよび圧縮レベルの向上に伴い、放射圧ノイズが主要な制限要因となる見込みである。周波数依存圧縮を実現するフィルタカビティの設置は、この放射圧ノイズの緩和を通じて量子ノイズの広帯域低減を可能にし、現在計画されているすべての将来の重力波検出器における基本アプローチとなっている。フィルタカビティの設計と運用には、干渉計の光力学特性および圧縮劣化プロセスの慎重な検討が不可欠である。本論文では、フィルタカビティの最適な動作点を決定するための詳細な解析を実施する。我々のモデルを数値ツールと併用し、今後の Advanced LIGO 検出器における「A+」アップグレードに設置予定のフィルタカビティに対する影響を検討する。
Vacuum quantum fluctuations impose a fundamental limit on the sensitivity of gravitational-wave interferometers, which rank among the most sensitive precision measurement devices ever built. The injection of conventional squeezed vacuum reduces quantum noise in one quadrature at the expense of increasing noise in the other. While this approach improved the sensitivity of the Advanced LIGO and Advanced Virgo interferometers during their third observing run (O3), future improvements in arm power and squeezing levels will bring radiation pressure noise to the forefront. Installation of a filter cavity for frequency-dependent squeezing provides broadband reduction of quantum noise through the mitigation of this radiation pressure noise, and it is the baseline approach planned for all of the future gravitational-wave detectors currently conceived. The design and operation of a filter cavity requires careful consideration of interferometer optomechanics as well as squeezing degradation processes. In this paper, we perform an in-depth analysis to determine the optimal operating point of a filter cavity. We use our model alongside numerical tools to study the implications for filter cavities to be installed in the upcoming "A+" upgrade of the Advanced LIGO detectors.