低温における KLauS ASIC の評価
Evaluation of the KLauS ASIC at low temperature
Evaluation of the KLauS ASIC at low temperature
@misc{wang2020evaluation,
title = {Evaluation of the KLauS ASIC at low temperature},
author = {Wei Wang and Wei Shen and Zhenxiong Yuan and Konrad Briggl and Hans-Christian Schultz-Coulon and Wenqi Yan and Guofu Cao and Zepeng Li and Ming Qi and Liangjian Wen},
year = {2020},
eprint = {2011.05643},
archivePrefix = {arXiv},
primaryClass = {physics.ins-det},
url = {https://arxiv.org/abs/2011.05643}
}
Wang, W., Shen, W., Yuan, Z., Briggl, K., Schultz-Coulon, H.-C., Yan, W., Cao, G., Li, Z., Qi, M., & Wen, L. (2020). Evaluation of the KLauS ASIC at low temperature [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.05643
WANG W, SHEN W, YUAN Z, et al. Evaluation of the KLauS ASIC at low temperature[EB/OL]. (2020-11-11)[2026-11-29]. https://arxiv.org/abs/2011.05643.
要旨
泰山反中微子観測所(TAO)は、大面積のシリコン光増倍管(SiPM)(10 m^2)を備えた低温液体シントリレーター検出器(-50 ^circC)を初めて使用し、1 MeV における記録的なエネルギー分解能< 2% で反中微子スペクトルを精密に測定することを目的としている。KLauS ASIC は室温で優れた性能を示し、TAO の読み出しソリューションの候補である。本稿では、KLauS ASIC の第 5 世代(KLauS5)を室温から -50 ^circC にかけて、注入された電荷または SiPM を入力として評価する結果を報告する。我々の結果は、KLauS5 が試験温度において良好な性能を示し、電荷ノイズ、電荷線形性、ゲイン均一性、回復時間において著しい劣化がないことを示している。同時に、チップが低温条件下で動作する際に、動的範囲と消費電力を含むいくつかの主要パラメータが劣化する現象も観察された。しかし、この劣化にもかかわらず、ゲインが 1.5x10^6 以上、かつ 1 チャンネルで最大 1 cm^2 の面積を持つ SiPM に対して、良好な信号対雑音比と単一光電子の分解能は達成可能である。これは、入力容量が約 5 nF に相当する。したがって、KLauS5 は TAO の精密電荷測定要件を満たすと結論付ける。
The Taishan Antineutrino Observatory (TAO) is proposed to first use a cold liquid scintillator detector (-50 ^circC) equipped with large-area silicon photomultipliers (SiPMs) (10 m^2) to precisely measure the reactor antineutrino spectrum with a record energy resolution of < 2% at 1 MeV. The KLauS ASIC shows excellent performance at room temperature and is a potential readout solution for TAO. In this work, we report evaluations of the fifth version of the KLauS ASIC (KLauS5) from room temperature to -50 ^circC with inputs of injected charge or SiPMs. Our results show that KLauS5 has good performance at the tested temperatures with no significant degradation of the charge noise, charge linearity, gain uniformity or recovery time. Meanwhile, we also observe that several key parameters degrade when the chip operates in cold conditions, including the dynamic range and power consumption. However, even with this degradation, a good signal-to-noise ratio and good resolution of a single photoelectron can still be achieved for the tested SiPM with a gain of greater than 1.5x10^6 and even an area of SiPM up to 1 cm^2 in one channel, corresponding to an input capacitance of approximately 5 nF. Thus, we conclude that KLauS5 can fulfill the TAO requirements for precise charge measurement.