Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging
Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging
@misc{mcaleer2020deep,
title = {Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging},
author = {Stephen McAleer and Alex Fast and Yuntian Xue and Magdalene Seiler and William Tang and Mihaela Balu and Pierre Baldi and Andrew W. Browne},
year = {2020},
eprint = {2011.06408},
archivePrefix = {arXiv},
primaryClass = {eess.IV},
url = {https://arxiv.org/abs/2011.06408}
}
McAleer, S., Fast, A., Xue, Y., Seiler, M., Tang, W., Balu, M., Baldi, P., & Browne, A. W. (2020). Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.06408
MCALEER S, FAST A, XUE Y, et al. Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging[EB/OL]. (2020-11-10)[2026-11-29]. https://arxiv.org/abs/2011.06408.
要旨
二光子励起蛍光顕微鏡法(2PEF)は、約 1 mm の厚さを持つ組織のイメージングを可能にする。通常、蛍光励起露光量の低減はイメージの品質を低下させるが、深層学習を用いた超解像技術により、これらの低解像度イメージを高解像度イメージに変換することが可能である。本稿では、深層学習を適用し、蛍光励起露光量を低減しつつイメージの品質を最大化することで、ヒト組織のイメージングを改善することを検討する。我々は、U-Net に基づく手法とパッチベースの回帰手法の 2 つの手法を分析した。両手法は、皮膚データセットと眼データセットで評価された。眼データセットには、網膜オルガノイドの高パワー・低パワーのペアイメージ 1,200 枚が含まれ、皮膚データセットには各サンプルの複数のフレームが含まれる。高解像度イメージは各サンプルの 70 フレームの平均から形成され、低解像度イメージは各サンプルの最初の 7 フレームおよび 15 フレームの平均から形成された。皮膚データセットには、各解像度レベルで 550 枚のイメージが含まれる。両手法の性能指標として、平均二乗誤差(MSE)と構造類似度指標(SSIM)の 2 つを追跡した。眼データセットにおいて、パッチ手法は平均 MSE が 27,611 で、U-Net 手法の 146,855 を下回り、平均 SSIM が 0.636 で U-Net 手法の 0.607 を上回った。皮膚データセットにおいて、パッチ手法は平均 MSE が 3.768 で U-Net 手法の 4.032 を下回り、平均 SSIM が 0.824 で U-Net 手法の 0.783 を上回った。イメージ品質においてパッチ手法が優れているにもかかわらず、予測速度の比較ではパッチ手法は U-Net 手法よりも劣り、1 枚のイメージの予測に 303 秒を要するのに対し、U-Net 手法は 1 秒未満である。
Two-photon excitation fluorescence (2PEF) allows imaging of tissue up to about one millimeter in thickness. Typically, reducing fluorescence excitation exposure reduces the quality of the image. However, using deep learning super resolution techniques, these low-resolution images can be converted to high-resolution images. This work explores improving human tissue imaging by applying deep learning to maximize image quality while reducing fluorescence excitation exposure. We analyze two methods: a method based on U-Net, and a patch-based regression method. Both methods are evaluated on a skin dataset and an eye dataset. The eye dataset includes 1200 paired high power and low power images of retinal organoids. The skin dataset contains multiple frames of each sample of human skin. High-resolution images were formed by averaging 70 frames for each sample and low-resolution images were formed by averaging the first 7 and 15 frames for each sample. The skin dataset includes 550 images for each of the resolution levels. We track two measures of performance for the two methods: mean squared error (MSE) and structural similarity index measure (SSIM). For the eye dataset, the patches method achieves an average MSE of 27,611 compared to 146,855 for the U-Net method, and an average SSIM of 0.636 compared to 0.607 for the U-Net method. For the skin dataset, the patches method achieves an average MSE of 3.768 compared to 4.032 for the U-Net method, and an average SSIM of 0.824 compared to 0.783 for the U-Net method. Despite better performance on image quality, the patches method is worse than the U-Net method when comparing the speed of prediction, taking 303 seconds to predict one image compared to less than one second for the U-Net method.