細胞および組織培養に誘導電磁場を供給するための新規 in vitro デバイス
A novel in vitro device to deliver induced electromagnetic fields to cell and tissue cultures
A novel in vitro device to deliver induced electromagnetic fields to cell and tissue cultures
@misc{ravin2020a,
title = {A novel in vitro device to deliver induced electromagnetic fields to cell and tissue cultures},
author = {Rea Ravin and Teddy X. Cai and Randall H. Pursley and Marcial Garmendia-Cedillos and Tom Pohida and Raisa Z. Freidlin and Herui Wang and Zhengping Zhuang and Amber J. Giles and Nathan H. Williamson and Mark R. Gilbert and Peter J. Basser},
year = {2020},
eprint = {2011.09698},
archivePrefix = {arXiv},
primaryClass = {physics.bio-ph},
url = {https://arxiv.org/abs/2011.09698}
}
Ravin, R., Cai, T. X., Pursley, R. H., Garmendia-Cedillos, M., Pohida, T., Freidlin, R. Z., Wang, H., Zhuang, Z., Giles, A. J., Williamson, N. H., Gilbert, M. R., & Basser, P. J. (2020). A novel in vitro device to deliver induced electromagnetic fields to cell and tissue cultures [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.09698
RAVIN R, CAI TX, PURSLEY RH, et al. A novel in vitro device to deliver induced electromagnetic fields to cell and tissue cultures[EB/OL]. (2020-11-19)[2026-11-29]. https://arxiv.org/abs/2011.09698.
要旨
我々は、誘導電磁場(EMF)をソレノイドコイルを用いて生成した細胞・組織培養に、中間周波数(100 - 400 kHz)、中等度強度(最大 6.5 V/cm pk-pk を超える)の電気場(EF)を届ける新しい in vitro 装置を開発した。これらの EF の主要な応用は、新興の癌治療法として挙げられる。Novocure Ltd. の in vitro 研究では、彼らが「腫瘍治療電場(TTFields)」と呼ぶ中間周波数(100 - 300 kHz)、低振幅(1 - 3 V/cm)の EF が、星形細胞腫多形(GBM)細胞に対して抗分裂作用を示すことが報告されている。この効果は EF の振幅が増加するにつれて増加することが確認された。理論的、臨床前、臨床研究が継続されているにもかかわらず、作用機序は完全に理解されていない。これまでの「TTFields」に関する in vitro 研究では、細胞・組織培養に交流 EF を届けるために接続された容量結合電極が用いられており、この接触型供給方法は EF プロファイルの特性が不明確で、導電性加熱を引き起こし、適用可能な EF の持続時間と振幅を制限する欠点がある。一方、我々の装置は非接触方式で、良好に特性化された放射状プロファイルの EF を供給し、導電性加熱を排除するとともに、熱調節された EF 供給を可能にする。我々のシステムの検証と実証のため、EF の振幅プロファイルが 0 - 6.5 V/cm pk-pk を含む連続 200 kHz の EMF を生成し、ヒト甲状腺細胞培養に 72 時間適用した。低 EF 振幅(< 4 V/cm)では細胞密度の中等度の低下(< 10%)を、高振幅(4 - 6.5 V/cm)では最大 25% の細胞密度の低下を観察した。我々の装置は他の EF 周波数と振幅の領域にも拡張可能である。今後、この装置を用いた研究は、EF の効果と作用機序をより明確に分離することにより、「TTFields」の有効性と作用機序に関する ongoing debate に貢献するはずである。
We have developed a novel in vitro instrument that can deliver intermediate frequency (100 - 400 kHz), moderate intensity (up to and exceeding 6.5 V/cm pk-pk) electric fields (EFs) to cell and tissue cultures generated using induced electromagnetic fields (EMFs) in a solenoid coil. A major application of these EFs is as an emerging cancer treatment modality. In vitro studies by Novocure Ltd. reported that intermediate frequency (100 - 300 kHz), low amplitude (1 - 3 V/cm) EFs, which they called "Tumor Treating Fields" (TTFields), had an anti-mitotic effect on glioblastoma multiforme (GBM) cells. The effect was found to increase with increasing EF amplitude. Despite continued theoretical, preclinical, and clinical study, the mechanism of action remains incompletely understood. Previous in vitro studies of "TTFields" have used attached, capacitively coupled electrodes to deliver alternating EFs to cell and tissue cultures. This contacting delivery method suffers from a poorly characterized EF profile and conductive heating that limits the duration and amplitude of the applied EFs. In contrast, our device delivers EFs with a well-characterized radial profile in a non-contacting manner, eliminating conductive heating and enabling thermally regulated EF delivery. To test and demonstrate our system, we generated continuous 200 kHz EMF with an EF amplitude profile spanning 0 - 6.5 V/cm pk-pk and applied them to human thyroid cell cultures for 72 hours. We observed moderate reduction in cell density (< 10%) at low EF amplitudes (< 4 V/cm) and a greater reduction in cell density of up to 25% at higher amplitudes (4 - 6.5 V/cm). Our device can be extended to other EF frequency and amplitude regimes. Future studies with this device should contribute to the ongoing debate about the efficacy and mechanism(s) of action of "TTFields" by better isolating the effects of EFs.