肝臓および腎臓における MRI 誘導高強度焦点超音波治療
MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney
MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney
@misc{senneville2020mriguided,
title = {MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney},
author = {Baudouin Denis de Senneville and Mario Ries and Wilbert Bartels and Chrit Moonen},
year = {2020},
eprint = {2011.10752},
archivePrefix = {arXiv},
primaryClass = {physics.med-ph},
url = {https://arxiv.org/abs/2011.10752}
}
Senneville, B. D. D., Ries, M., Bartels, W., & Moonen, C. (2020). MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.10752
SENNEVILLE BDD, RIES M, BARTELS W, et al. MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney[EB/OL]. (2020-11-21)[2026-11-29]. https://arxiv.org/abs/2011.10752.
要旨
高強度焦点超音波(HIFU)は、侵襲的でない方法で人体の深部で局所的な温度上昇を達成するために使用できる。MRI をガイドすることで、in situ のターゲット定義が可能となる。さらに、HIFU 処理中の連続的な温度マッピングを提供することで、加熱プロセスの空間的・時間的制御および、受けた熱的用量に基づき最終的な損傷域の予測を行うことができる。腎臓や肝臓などの移動臓器の温度マッピング、および HIFU プロセスのフィードバック制御のためのリアルタイム処理手法は、依然として課題となっている。本稿では、これらの臓器の MRI 温度マッピング、HIFU ビームの運動補償、肋間 HIFU 超音波照射、および体積内焼灼とフィードバック制御戦略に関する最近の技術的進展をレビューする。最近の臨床前研究は、これらの新しい手法のそれぞれの実用可能性を証明している。これらの進展を臨床現場へ転換するための展望について述べる。結論として、肝臓および腎臓における焼灼のための MRI ガイド HIFU は実用可能であるが、技術的に高度な手法の統合に関するさらなる作業が必要である。
High Intensity Focused Ultrasound (HIFU) can be used to achieve a local temperature increase deep inside the human body in a non-invasive way. MRI guidance of the procedure allows in situ target definition. In addition, MRI can be used to provide continuous temperature mapping during HIFU for spatial and temporal control of the heating procedure and prediction of the final lesion based on the received thermal dose. Temperature mapping of mobile organs as kidney and liver is challenging, as well as real-time processing methods for feedback control of the HIFU procedure. In this paper, recent technological advances are reviewed in MR temperature mapping of these organs, in motion compensation of the HIFU beam, in intercostal HIFU sonication, and in volumetric ablation and feedback control strategies. Recent pre-clinical studies have demonstrated the feasibility of each of these novel methods. The perspectives to translate those advances into the clinic are addressed. It can be concluded that MR guided HIFU for ablation in liver and kidney appears feasible but requires further work on integration of technologically advanced methods.