放射線治療におけるドーズペイントのための機能画像
Functional Imaging for Dose Painting in Radiotherapy
Functional Imaging for Dose Painting in Radiotherapy
@misc{pang2020functional,
title = {Functional Imaging for Dose Painting in Radiotherapy},
author = {Yaru Pang and Gary Royle and Spyros Manolopoulos},
year = {2020},
eprint = {2011.11531},
archivePrefix = {arXiv},
primaryClass = {physics.med-ph},
url = {https://arxiv.org/abs/2011.11531}
}
Pang, Y., Royle, G., & Manolopoulos, S. (2020). Functional Imaging for Dose Painting in Radiotherapy [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.11531
PANG Y, ROYLE G, MANOLOPOULOS S. Functional Imaging for Dose Painting in Radiotherapy[EB/OL]. (2020-11-23)[2026-11-29]. https://arxiv.org/abs/2011.11531.
要旨
ドーズペイントは、健康な領域への毒性を増加させずに標的領域に必要な線量を調節するために開発された。腫瘍の正確な位置とサイズを決定するだけでなく、定量的機能画像を用いてドーズペイントを実装できる。マルチパラメータ MRI や PET-CT などの機能画像は、巨視的腫瘍容積内の治療抵抗性の領域やボクセルへの線量増加と、より攻撃性の低い領域やボクセルへの線量低減を通じて、生学的線量昇格を実現することを可能にする。生学的線量昇格は、微小組織特性に基づく放射線治療における治療介入の指標として機能する。このような生学的指標を用いることで、ドーズペイントにより特定の境界線やボクセルに合わせた個別化された放射線線量を設計できる。本レビューでは、まず PET-CT とマルチパラメータ MRI を含む複数の定量的機能画像技術を議論する。さらに、境界線によるドーズペイント(DPBC)と数によるドーズペイント(DPBN)の理論的・実験的比較、およびドーズペイント後の結果解析を提供する。最後に、この分野における主要な課題と将来の方向性をまとめ、刺激的な発展と有益な研究分野の啓発を願う。
Dose painting has been developed to modulate the required dose in the target area without increasing the toxicity in healthy areas. Apart from determining the accurate location and size of tumors, quantitative functional imaging can be used to implement the dose painting. Functional imaging, such as multi-parameter MRI and PET CT, allows us to achieve biological dose escalation by increasing the dose in certain areas or voxels that are therapy-resistant in the gross tumor volume while reducing the dose in the less aggressive area or voxels. Functional imaging can serve as an indicator of therapeutic intervention in radiotherapy due to microscopic tissue properties. With such biological indicators, the personalized radiation dose can be tailored to a specific contour or a voxel using dose painting. In this review, we firstly discuss several quantitative functional imaging techniques including PET-CT and multi-parameter MRI. Furthermore, theoretical and experimental comparisons for dose painting by contours (DPBC) and dose painting by numbers (DPBN), along with outcome analysis after dose painting are provided. Finally, we conclude major challenges and future directions in this field through which we hope to inspire exciting developments and fruitful research avenues.