X 線コンピュータ断層撮影のためのディープインタラクティブデノイザー(DID)
Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
@misc{bai2020deep,
title = {Deep Interactive Denoiser (DID) for X-Ray Computed Tomography},
author = {Ti Bai and Biling Wang and Dan Nguyen and Bao Wang and Bin Dong and Wenxiang Cong and Mannudeep K. Kalra and Steve Jiang},
year = {2020},
eprint = {2011.14873},
archivePrefix = {arXiv},
primaryClass = {eess.IV},
url = {https://arxiv.org/abs/2011.14873}
}
Bai, T., Wang, B., Nguyen, D., Wang, B., Dong, B., Cong, W., Kalra, M. K., & Jiang, S. (2020). Deep Interactive Denoiser (DID) for X-Ray Computed Tomography [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.14873
BAI T, WANG B, NGUYEN D, et al. Deep Interactive Denoiser (DID) for X-Ray Computed Tomography[EB/OL]. (2020-11-30)[2026-11-29]. https://arxiv.org/abs/2011.14873.
要旨
低線量コンピュータ断層撮影(LDCT)は、診断画像化および画像誘導介入の両方において望ましい。LDCT の品質向上には、オープンソースのデノイザーが広く利用されている。ディープラーニング(DL)ベースのデノイザーは、最先端の性能を示しており、主流の方法の一つとなっている。しかし、DL ベースのデノイザーには 2 つの課題が存在する:1)トレーニングされたモデルは、異なる臨床タスクに必要な異なるノイズ・解像度トレードオフを持つ複数の画像候補を生成しない;2)テスト画像のノイズレベルがトレーニングデータセットのノイズレベルと異なる場合、モデルの汎化能力に問題が生じる可能性がある。これらの課題に対処するため、本稿では、既存の任意の DL ベースのデノイザーのテストフェーズ上に、軽量な最適化プロセスを導入し、異なる臨床タスクに適した複数のノイズ・解像度トレードオフを持つ画像候補をリアルタイムで生成する。これにより、本手法はユーザーがデノイザーと相互作用し、効率的に複数の画像候補をレビューし、望ましいものを選択することを可能にし、深層インタラクティブデノイザー(DID)と称される。実験結果は、DID が異なるノイズ・解像度トレードオフを持つ複数の画像候補を提供でき、また、異なるネットワークアーキテクチャ、および異なるノイズレベルのトレーニングおよびテストデータセットに対して優れた汎化能力を示すことを示している。
Low dose computed tomography (LDCT) is desirable for both diagnostic imaging and image guided interventions. Denoisers are openly used to improve the quality of LDCT. Deep learning (DL)-based denoisers have shown state-of-the-art performance and are becoming one of the mainstream methods. However, there exists two challenges regarding the DL-based denoisers: 1) a trained model typically does not generate different image candidates with different noise-resolution tradeoffs which sometimes are needed for different clinical tasks; 2) the model generalizability might be an issue when the noise level in the testing images is different from that in the training dataset. To address these two challenges, in this work, we introduce a lightweight optimization process at the testing phase on top of any existing DL-based denoisers to generate multiple image candidates with different noise-resolution tradeoffs suitable for different clinical tasks in real-time. Consequently, our method allows the users to interact with the denoiser to efficiently review various image candidates and quickly pick up the desired one, and thereby was termed as deep interactive denoiser (DID). Experimental results demonstrated that DID can deliver multiple image candidates with different noise-resolution tradeoffs, and shows great generalizability regarding various network architectures, as well as training and testing datasets with various noise levels.