単一ピクセルカメラ構成における空間時間散乱点パターンによる蛍光寿命イメージング
Fluorescence lifetime imaging via spatio-temporal speckle patterns in single-pixel camera configuration
Fluorescence lifetime imaging via spatio-temporal speckle patterns in single-pixel camera configuration
@misc{junek2020fluorescence,
title = {Fluorescence lifetime imaging via spatio-temporal speckle patterns in single-pixel camera configuration},
author = {Jiri Junek and Karel Zidek},
year = {2020},
eprint = {2012.02605},
archivePrefix = {arXiv},
primaryClass = {physics.optics},
url = {https://arxiv.org/abs/2012.02605}
}
Junek, J., & Zidek, K. (2020). Fluorescence lifetime imaging via spatio-temporal speckle patterns in single-pixel camera configuration [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2012.02605
JUNEK J, ZIDEK K. Fluorescence lifetime imaging via spatio-temporal speckle patterns in single-pixel camera configuration[EB/OL]. (2020-12-04)[2026-11-29]. https://arxiv.org/abs/2012.02605.
要旨
光発光(PL)分光法は、ナノ秒時間スケールにおける PL 減衰のマッピングに優れた手法を提供する。しかし、マイクロ秒時間スケールにおける発光ダイナミクスマップの取得は非常に時間がかかる。本研究では、ランダム時間的なスッペル励起(RATS)の概念と、空間的なスッペルに基づく単一ピクセルカメラの概念を組み合わせた新しい蛍光寿命イメージング(FLIM)のアプローチを提案する。空間時間的なスッペルパターンにより、これまでになく単純な方法で PL ダイナミクスをマッピングすることが可能となる。さらに、本手法は数分以内にマイクロ秒時間スケールにおける PL 減衰をマッピングするために必要なすべてのデータを取得できる。本研究では、2 つのサンプルに対する原理検証測定を行い、再構成された減衰曲線と非イメージング測定結果を比較した。最後に、再構成ノイズレベルに対する前処理ルーチンおよびその他の要因の影響について議論する。本手法は、ペロブスカイトにおける電荷キャリアダイナミクスや、PL 寿命が長い固体発光体モニタリングなど、複数のサンプルにおける寿命イメージングプロセスに適している。
Photoluminesce (PL) spectroscopy offers excellent methods for mapping the PL decay on the nanosecond time scale. However, capturing maps of emission dynamics on the microsecond time scale can be highly time-consuming. We present a new approach to fluorescence lifetime imaging FLIM, which combines the concept of random temporal speckles excitation (RATS) with the concept of a single-pixel camera based on spatial speckles. The spatio-temporal speckle pattern makes it possible to map PL dynamics with unmatched simplicity. Moreover, the method can acquire all data necessary to map PL decays in the microsecond timescale within minutes. We present proof of principle measurements for two samples and compare the reconstructed decays to the non-imaging measurements. Finally, we discuss the effect of the preprocessing routine and other factors on the reconstruction noise level. The presented method is suitable for lifetime imaging processes in several samples, including charge carrier dynamics in perovskites or monitoring solid-state luminophores with a long lifetime of PL.