근접, 원거리, 어디에 있든: 홀로그래픽 및 피치코그래픽 결맞은 이미징의 선량 효율성에 대한 시뮬레이션
Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging
Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging
@misc{du2019near,
title = {Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging},
author = {Ming Du and Doga Gursoy and Chris Jacobsen},
year = {2019},
eprint = {1908.06770},
archivePrefix = {arXiv},
primaryClass = {eess.IV},
url = {https://arxiv.org/abs/1908.06770}
}
Du, M., Gursoy, D., & Jacobsen, C. (2019). Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging [Preprint]. arXiv. https://doi.org/10.48550/arXiv.1908.06770
DU M, GURSOY D, JACOBSEN C. Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging[EB/OL]. (2019-08-16)[2026-11-29]. https://arxiv.org/abs/1908.06770.
초록
x-ray 미시경 연구들에서 시편 후방의 근접 (Fresnel 영역) 또는 원거리 (Fraunhofer 영역) 장에서 강도 분포를 기록하는 이미징 모드의 선량 효율성에 대해 상반된 결론을 도출해 왔습니다. 본 논문에서는 시편에 동일한 플루언스를 적용할 때 모든 세 가지 방법 (근접 홀로그래피 (NFH), 근접 피토그래피 (NFP), 원거리 피토그래피 (FFP)) 이 유사한 이미지 품질을 제공함을 수치 연구로 확인합니다. 여기서 피토그래피는 중첩된 유한 크기의 조명 위치를 포함합니다. 일관성 회절 이미징 (CDI) 에서 보고된 바와 달리, 원거리 피토그래피가 약간 더 높은 공간 분해능과 낮은 평균 오차를 제공함을 발견합니다. 이러한 결과는 실험 및 이미지 재구성 (image reconstruction) 이 올바르게 수행된다면 시편이 근접하거나 원거리이든 상관없이, 시편에 작용하는 광자 플루언스가 공간 분해능의 한계를 설정한다는 개념을 지지합니다.
Different studies in x-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. We present here a numerical study on the dose efficiency of near-field holography (NFH), near-field ptychography (NFP), and far-field ptychography (FFP), where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging (CDI), which involves recording a single far-field diffraction pattern, we find that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near, or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.