해석학적 분석을 기반으로 초음속 난류 공동 유동의 비정상 제어
Unsteady control of supersonic turbulent cavity flow based on resolvent analysis
Unsteady control of supersonic turbulent cavity flow based on resolvent analysis
@misc{liu2020unsteady,
title = {Unsteady control of supersonic turbulent cavity flow based on resolvent analysis},
author = {Qiong Liu and Yiyang Sun and Chi-An Yeh and Lawrence S. Ukeiley and Louis N. Cattafesta III and Kunihiko Taira},
year = {2020},
eprint = {2003.10091},
archivePrefix = {arXiv},
primaryClass = {physics.flu-dyn},
url = {https://arxiv.org/abs/2003.10091}
}
Liu, Q., Sun, Y., Yeh, C.-A., Ukeiley, L. S., III, L. N. C., & Taira, K. (2020). Unsteady control of supersonic turbulent cavity flow based on resolvent analysis [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2003.10091
LIU Q, SUN Y, YEH CA, et al. Unsteady control of supersonic turbulent cavity flow based on resolvent analysis[EB/OL]. (2020-03-23)[2026-11-29]. https://arxiv.org/abs/2003.10091.
초록
압력 요동을 완화하기 위해 마하수 1.4, 깊이 기준 레이놀즈 수 10,000, 길이-깊이 비율 6 을 갖는 직사각형 공동 내 난류 초음속 유동에서 비정상적 활성 제어 설치를 결정하기 위해 분해능 분석을 사용한다. 초음속 공동 유동의 대 와동 시뮬레이션 (LES) 과 동적 모달 분해 (DMD) 는 2 차원 로시터 모드 II 와 IV 의 우세함을 보여준다. 이 주된 2 차원 와동 구조는 후단 가장자리 충격으로 인해 공동 전체에 걸쳐 고 진폭의 비정상을 생성하며, 자유 유동을 방해하여 경사 충격파를 형성한다. 와동 구조의 원치 않는 형성을 방해하기 위해 공동 전단 가장자리에서 3 차원 비정상적 강제력을 도입하여 종방향 와동 구조를 생성한다. 시간 평균된 기본 유동에 대한 분해능 분석을 활용하여 최적의 강제력 주파수와 횡파수를 결정한다. 가장 증폭된 분해능 강제력 모드를 선택하는 대신, 공동 전체 길이에 걸쳐 주 분해능 기반 운동 에너지 분포를 지속적으로 증폭시키는 제어 매개변수 조합을 추구한다. 지속적 증폭은 선택된 강제력 입력이 큰 횡방향 와동 형성을 방지하는 데 효과적으로 유지되도록 보장하는 데 필수적이다. 이 분해능 분석 기반 유동 제어 지침은 제어된 공동 유동의 여러 동반 LES 와 검증되었다. 최적 제어 설치는 기준 공동 유동에 비해 후단 및 하단 공동 벽을 따라 압력 제곱근 평균 수준을 최대 52%까지 감소시키는 것으로 가장 효과적임이 확인되었다. 본 분해능 분석에서 유도된 유동 제어 지침은 강제력 입력이 관심 영역의 넓은 영역에 걸쳐 효과적으로 유지되어야 하는 유동에 적용 가능해야 한다.
We use resolvent analysis to determine an unsteady active control setup to attenuate pressure fluctuations in turbulent supersonic flow over a rectangular cavity with a length-to-depth ratio of 6 at a Mach number of 1.4 and a Reynolds number based on cavity depth of 10,000. Large-eddy simulations (LES) and dynamic modal decomposition (DMD) of the supersonic cavity flow reveal the dominance of two-dimensional Rossiter modes II and IV. These predominantly two-dimensional vortical structures generate high-amplitude unsteadiness over the cavity through trailing-edge impingement and create oblique shock waves by obstructing the freestream. To disrupt the undesired formation of vortical structures, we introduce three-dimensional unsteady forcing along the cavity leading edge to generate streamwise vortical structures. Resolvent analysis with respect to the time-averaged base flow is leveraged to determine the optimal combination of forcing frequency and spanwise wavenumber. Instead of selecting the most amplified resolvent forcing modes, we seek the combination of control parameters that yields sustained amplification of the primary resolvent-based kinetic energy distribution over the entire length of the cavity. The sustained amplification is critical to ensure that the selected forcing input remains effective to prevent the formation of the large spanwise vortices. This resolvent-analysis-based flow control guideline is validated with a number of companion LES of the controlled cavity flows. The optimal control setup is verified to be the most effective in reducing the pressure root-mean-square level up to 52% along the aft and bottom cavity walls compared to the baseline cavity flow. The present flow control guideline derived from resolvent analysis should be applicable to flows that require the actuation input to remain effective over an extended region of interest.