동적 MRI 의 데이터 기반 정규화 파라미터 선택
Data-driven regularization parameter selection in dynamic MRI
Data-driven regularization parameter selection in dynamic MRI
@misc{hanhela2020datadriven,
title = {Data-driven regularization parameter selection in dynamic MRI},
author = {Matti Hanhela and Olli Gröhn and Mikko Kettunen and Kati Niinimäki and Marko Vauhkonen and Ville Kolehmainen},
year = {2020},
eprint = {2004.01707},
archivePrefix = {arXiv},
primaryClass = {physics.med-ph},
url = {https://arxiv.org/abs/2004.01707}
}
Hanhela, M., Gröhn, O., Kettunen, M., Niinimäki, K., Vauhkonen, M., & Kolehmainen, V. (2020). Data-driven regularization parameter selection in dynamic MRI [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2004.01707
HANHELA M, GRÖHN O, KETTUNEN M, et al. Data-driven regularization parameter selection in dynamic MRI[EB/OL]. (2020-04-03)[2026-11-29]. https://arxiv.org/abs/2004.01707.
초록
동적 MRI 에서 시간 해상도를 확보하기 위해서는 시간 시리즈의 각 이미지에 대해 과소 샘플링된 데이터를 생성하는 영상 프로토콜을 사용하는 것이 종종 필수적이다. 이는 압축 센싱 (CS) 기반 이미지 재구성 접근법의 인기가 높아진 원인이 되었다. CS 접근법 중 하나는 데이터 충실도와 공간 및 시간 정규화 항 사이의 균형을 조절하는 정규화 파라미터를 결정하는 문제이다. 본 논문은 정규화 도메인에서 기대되는 희소성을 달성하도록 총 변동 정규화 파라미터 선택을 위한 데이터 기반 접근법을 제안한다. 기대되는 희소성은 시간 정규화를 위해 측정 데이터에서, 공간 정규화를 위해 참조 이미지에서 얻어진다. 두 가지 공식화가 제안된다. 첫 번째는 시간 및 공간 정규화 도메인에서 모두 기대되는 희소성을 생성하는 파라미터 쌍에 대한 2 차원 탐색이다. 두 번째 접근법에서는 희소성 기반 파라미터 선택을 S 곡선 방법을 사용하여 두 개의 1 차원 탐색으로 분리한다. 본 방법들은 시뮬레이션 및 실험적 DCE-MRI 를 사용하여 평가되었다. 시뮬레이션 테스트 사례에서 제안된 두 방법 모두 RMSE 최적 파라미터 쌍에 가까운 파라미터 쌍을 생성하며, 재구성 오차도 최소에 가깝다. 실험 테스트 사례에서 두 방법은 거의 유사한 파라미터 선택을 수행하며, 재구성은 높은 주관적 품질을 보인다. 두 접근법 모두 시뮬레이션 및 실험 테스트 사례에서 시간 및 공간 정규화 파라미터의 선택을 매우 실현 가능하게 만들었으며, 순차적 방법은 계산적으로 더 효율적이다.
In dynamic MRI, sufficient time resolution can often only be obtained using imaging protocols which produce undersampled data for each image in the time series. This has led to the popularity of compressed sensing (CS) based image reconstruction approaches. One of the problems in CS approaches is determining the regularization parameters, which control the balance between data fidelity the spatial and temporal regularization terms. A data-driven approach is proposed for the total variation regularization parameter selection such that the reconstructions yield expected sparsity levels in the regularization domains. The expected sparsity levels are obtained from the measurement data for the temporal regularization and from a reference image for the spatial regularization. Two formulations are proposed. The first is a 2D search for a parameter pair which produces expected sparsity in both the temporal and spatial regularization domains. In the second approach, the sparsity-based parameter selection is split to two 1D searches using the S-curve method. The approaches are evaluated using simulated and experimental DCE-MRI. In the simulated test case, both proposed methods produce a parameter pair that is close to the RMSE optimal pair, and the reconstruction error is also close to minimum. In the experimental test case, the methods produce almost similar parameter selection, and the reconstructions are of high perceived quality. Both approaches lead to a highly feasible selection of the temporal and spatial regularization parameters in both the simulated and experimental test cases while the sequential method is computationally more efficient.