COVID-19 상황 하에서 비접촉식 안과 검사 중 각막 눈물막에서 방출되는 방울의 역학
Dynamics of Droplet Generation from Corneal Tear Film during Non-contact Eye Procedure in the Context of COVID-19
Dynamics of Droplet Generation from Corneal Tear Film during Non-contact Eye Procedure in the Context of COVID-19
@misc{roy2020dynamics,
title = {Dynamics of Droplet Generation from Corneal Tear Film during Non-contact Eye Procedure in the Context of COVID-19},
author = {Durbar Roy and Sophia M and Abdur Rasheed and Prasenjit Kabi and Abhijit Sinha Roy and Rohit Shetty and Saptarshi Basu},
year = {2020},
eprint = {2011.01228},
archivePrefix = {arXiv},
primaryClass = {physics.med-ph},
url = {https://arxiv.org/abs/2011.01228}
}
Roy, D., M, S., Rasheed, A., Kabi, P., Roy, A. S., Shetty, R., & Basu, S. (2020). Dynamics of Droplet Generation from Corneal Tear Film during Non-contact Eye Procedure in the Context of COVID-19 [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.01228
ROY D, M S, RASHEED A, et al. Dynamics of Droplet Generation from Corneal Tear Film during Non-contact Eye Procedure in the Context of COVID-19[EB/OL]. (2020-11-02)[2026-11-29]. https://arxiv.org/abs/2011.01228.
초록
비침습적 의료 진단은 방울 생성 경향이 있어 SARS-CoV-2 바이러스 전파 방지를 위한 위험 완화 전략 수립을 위해 연구되어야 한다. 본 연구는 인공수압계를 이용한 공기 분사 톨로메트리 (air-puff tonometry) 를 조사한다. 이 방법은 짧은 시간 동안의 공기 분사를 사용하여 인간 눈을 압착함으로써 안압을 측정하여 녹내장의 초기 발현을 탐지한다. 공기 분사는 와류와 고속 제트가 뒤따르는 구조로 구성된다. 일반적인 톨로메트리 측정 중 눈의 고속 영상은 눈물 층과 공기 분사 사이의 상호작용으로 시작하여 초기 시트 방출로 이어지는 일련의 사건을 보여준다. 이는 곧 뒤따르는 제트가 중앙 각막 섹션을 압착하여 모세파를 형성하고, 이 모세파가 고도로 3 차원적이며 일시적으로 확장되는 시트와 상호작용하게 한다. 뒤따르는 제트에 의한 모세파 및 주변 공기장의 상호작용으로 인해 확장되는 시트는 가방 분해 (bag breakup), 레일리 - 테일러 불안정성에 의한 손가락 형성을 거쳐 다시 레일리 - 플로우 불안정성에 의해 후속 방울로 분해된다. 이 방울들은 주변 물체에 튀어 퍼져 포마이트 (fomites) 나 에어로졸을 형성할 수 있으며, 이는 감염을 유발할 수 있다. 이러한 복잡한 공간 - 시간 현상은 엄밀한 실험을 통해 정밀하게 문서화되었으며, 포괄적인 이론적 분석으로 입증되었다.
Non-invasive medical diagnostics demonstrate a propensity for droplet generation and should be studied to devise risk mitigation strategies against the spread of the SARS-CoV-2 virus. We investigate the air-puff tonometry, which uses a short-timed air-puff to applanate the human eye in a bid to detect the early onset of glaucoma by measuring the intraocular pressure. The air-puff consists of a vortex trailed by a high-speed jet. High-speed imaging of the eye during a typical tonometry measurement reveals a sequence of events starting with the interaction between the tear layer and the air puff leading to an initial sheet ejection. It is immediately followed by the trailing jet applanating the central corneal section, causing capillary waves to form and interact with the highly 3D transient expanding sheet. Such interaction with the capillary waves and the surrounding airfield due to the trailing jet causes the expanding sheet to undergo bag breakup, finger formation by Rayleigh Taylor instability and further break up into subsequent droplets by Rayleigh Plateau instability, which eventually splashes onto nearby objects, potentially forming fomites or aerosols which can lead to infections. The complex spatiotemporal phenomenon is carefully documented by rigorous experiments and corroborated using comprehensive theoretical analyses.