완전 전도성 첫 벽 극한에서의 ITER 차가운 VDE
ITER cold VDEs in the limit of a perfectly conducting first wall
ITER cold VDEs in the limit of a perfectly conducting first wall
@misc{clauser2020iter,
title = {ITER cold VDEs in the limit of a perfectly conducting first wall},
author = {C. F. Clauser and S. C. Jardin},
year = {2020},
eprint = {2011.05485},
archivePrefix = {arXiv},
primaryClass = {physics.plasm-ph},
url = {https://arxiv.org/abs/2011.05485}
}
Clauser, C. F., & Jardin, S. C. (2020). ITER cold VDEs in the limit of a perfectly conducting first wall [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.05485
CLAUSER CF, JARDIN SC. ITER cold VDEs in the limit of a perfectly conducting first wall[EB/OL]. (2020-11-11)[2026-11-29]. https://arxiv.org/abs/2011.05485.
초록
최근 Boozer [A. H. Boozer, Physics of Plasmas 26 114501 (2019)] 의 연구에 따르면, ITER 에서 벽이 완전 도체라고 가정하더라도 전류 퀘치 (current quench) 의 결과로 수직 이격 사건 (VDE) 이 발생할 수 있음이 밝혀졌다. 우리는 ITER 유사 평형 (equilibrium) 을 사용하여 M3D-C1 확장 MHD 코드를 적용하고, 완전 도체 벽 극한에서의 차가운 VDE 를 탐구하기 위해 전류 퀘치를 유도하였다. 다양한 벽 기하학을 적용하였다. 특히 플라즈마에서 멀리 떨어진 측면 벽을 가진 직사각형 벽의 경우, Boozer 가 개발한 상/하 평판 벽을 고려한 해석 모델과 매우 좋은 일치도를 얻었다. 측면 벽을 플라즈마에 더 가까이 가져오면 플라즈마가 초기 평형 위치에서 안정적으로 유지되는 해가 개선됨을 보였다. ITER 1 차 벽을 완전 도체 극한으로 사용할 때, 평판 벽 극한으로 예측한 값보다 훨씬 더 멀리 초기 평형 위치에서 안정적으로 유지된다. 반면, ITER 진공 용기의 내층이 완전 도체로 작용하는 극한을 고려할 때, 전류 퀘치 동안 플라즈마는 이격되지만 전류 감소 과정에서 평판 벽 극한에 비해 안전 계수 (safety factor) 가 2 보다 더 오래 유지된다. 모든 시뮬레이션 사례에서 수직 이격은 플라즈마 전류에 강하게 의존하는 것으로 발견되었으며, 이는 평판 벽 극한에서 유사한 결과를 보여 usual VDE 와는 전류 퀘치가 필수 조건이 아니라는 중요한 차이점을 시사한다.
Recently, it has been shown that a vertical displacement event (VDE) can occur in ITER even when the walls are perfect conductors, as a consequence of the current quench [A. H. Boozer, Physics of Plasmas 26 114501 (2019)]. We used the extended-MHD code M3D-C1 with an ITER-like equilibrium and induced a current quench to explore cold VDEs in the limit of perfectly conducting walls, using different wall geometries. In the particular case of a rectangular wall with the side walls far away from the plasma, we obtained very good agreement with the analytical model developed by Boozer that considers a top/bottom flat-plates wall. We show that the solution in which the plasma stays at the initial equilibrium position is improved when bringing the side walls closer to the plasma. When using the ITER first wall in the limit of a perfect conductor, the plasma stays stable at the initial equilibrium position far beyond the value predicted by the flat-plates wall limit. On the other hand, when considering the limit in which the inner shell of the ITER vacuum vessel is acting as a perfect conductor, the plasma is displaced during the current quench but the edge safety factor stays above 2 longer in the current decay compared to the flat-plates wall limit. In all the simulated cases, the vertical displacement is found to be strongly dependent on the plasma current, in agreement with a similar finding in the flat-plates wall limit, showing an important difference with usual VDEs in which the current quench is not a necessary condition.