저온에서의 KLauS ASIC 평가
Evaluation of the KLauS ASIC at low temperature
Evaluation of the KLauS ASIC at low temperature
@misc{wang2020evaluation,
title = {Evaluation of the KLauS ASIC at low temperature},
author = {Wei Wang and Wei Shen and Zhenxiong Yuan and Konrad Briggl and Hans-Christian Schultz-Coulon and Wenqi Yan and Guofu Cao and Zepeng Li and Ming Qi and Liangjian Wen},
year = {2020},
eprint = {2011.05643},
archivePrefix = {arXiv},
primaryClass = {physics.ins-det},
url = {https://arxiv.org/abs/2011.05643}
}
Wang, W., Shen, W., Yuan, Z., Briggl, K., Schultz-Coulon, H.-C., Yan, W., Cao, G., Li, Z., Qi, M., & Wen, L. (2020). Evaluation of the KLauS ASIC at low temperature [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.05643
WANG W, SHEN W, YUAN Z, et al. Evaluation of the KLauS ASIC at low temperature[EB/OL]. (2020-11-11)[2026-11-29]. https://arxiv.org/abs/2011.05643.
초록
태산 반중성자 관측소 (TAO) 는 차가운 액체 스킨틸레이터 검출기 (-50 ^circC) 에 대형 영역 실리콘 광증배관 (SiPMs) (10 m^2) 을 장착하여 1 MeV 에서 기록적인 에너지 분해능 (< 2%) 으로 반중성자 스펙트럼을 정밀하게 측정하는 것을 목표로 제안되었다. KLauS ASIC 은 상온에서 우수한 성능을 보이며 TAO 의 잠재적인 판독 솔루션이다. 본 연구에서는 상온부터 -50 ^circC 까지 KLauS ASIC 의 다섯 번째 버전 (KLauS5) 을 주입된 전하 또는 SiPMs 입력으로 평가하였다. 우리의 결과는 KLauS5 가 테스트된 온도에서 좋은 성능을 보이며 전하 노이즈, 전하 선형성, 이득 균일성 또는 회복 시간이 유의미하게 저하되지 않는다는 것을 보여준다. 동시에, 칩이 차가운 조건에서 작동할 때 동적 범위와 전력 소비를 포함한 몇 가지 주요 파라미터가 저하됨을 관찰하였다. 그러나 이러한 저하를 고려하더라도 이득이 1.5x10^6 보다 크고 하나의 채널에서 최대 1 cm^2 면적을 갖는 SiPM 에 대해 단일 광전자의 좋은 신호 대 잡음비와 좋은 분해능을 달성할 수 있다. 이는 약 5 nF 의 입력 용량에 해당한다. 따라서 우리는 KLauS5 가 TAO 의 정밀한 전하 측정을 위한 요구 사항을 충족할 수 있다고 결론지었다.
The Taishan Antineutrino Observatory (TAO) is proposed to first use a cold liquid scintillator detector (-50 ^circC) equipped with large-area silicon photomultipliers (SiPMs) (10 m^2) to precisely measure the reactor antineutrino spectrum with a record energy resolution of < 2% at 1 MeV. The KLauS ASIC shows excellent performance at room temperature and is a potential readout solution for TAO. In this work, we report evaluations of the fifth version of the KLauS ASIC (KLauS5) from room temperature to -50 ^circC with inputs of injected charge or SiPMs. Our results show that KLauS5 has good performance at the tested temperatures with no significant degradation of the charge noise, charge linearity, gain uniformity or recovery time. Meanwhile, we also observe that several key parameters degrade when the chip operates in cold conditions, including the dynamic range and power consumption. However, even with this degradation, a good signal-to-noise ratio and good resolution of a single photoelectron can still be achieved for the tested SiPM with a gain of greater than 1.5x10^6 and even an area of SiPM up to 1 cm^2 in one channel, corresponding to an input capacitance of approximately 5 nF. Thus, we conclude that KLauS5 can fulfill the TAO requirements for precise charge measurement.