Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging
Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging
@misc{mcaleer2020deep,
title = {Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging},
author = {Stephen McAleer and Alex Fast and Yuntian Xue and Magdalene Seiler and William Tang and Mihaela Balu and Pierre Baldi and Andrew W. Browne},
year = {2020},
eprint = {2011.06408},
archivePrefix = {arXiv},
primaryClass = {eess.IV},
url = {https://arxiv.org/abs/2011.06408}
}
McAleer, S., Fast, A., Xue, Y., Seiler, M., Tang, W., Balu, M., Baldi, P., & Browne, A. W. (2020). Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.06408
MCALEER S, FAST A, XUE Y, et al. Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging[EB/OL]. (2020-11-10)[2026-11-29]. https://arxiv.org/abs/2011.06408.
초록
이중 광자 여기 형광 (2PEF) 은 약 1 mm 두께의 조직 이미징을 가능하게 한다. 일반적으로 형광 여기 노출을 감소시키면 이미지 품질이 저하된다. 그러나 딥러닝 초해상도 기법을 적용하면 이러한 저해상도 이미지를 고해상도 이미지로 변환할 수 있다. 본 연구는 형광 여기 노출을 감소시키면서 이미지 품질을 최대화하기 위해 딥러닝을 적용하여 인간 조직 이미징을 개선하는 방법을 탐구한다. 우리는 U-Net 기반 방법과 패치 기반 회귀 방법을 분석한다. 두 방법은 피부 데이터셋과 눈 데이터셋에서 평가된다. 눈 데이터셋은 망막 기관아체 (retinal organoids) 의 고출력 및 저출력 이미지 1,200 쌍을 포함한다. 피부 데이터셋은 각 샘플의 여러 프레임으로 구성된다. 고해상도 이미지는 각 샘플의 70 프레임 평균으로 형성되었고, 저해상도 이미지는 각 샘플의 첫 번째 7 프레임과 15 프레임 평균으로 형성되었다. 피부 데이터셋은 각 해상도 수준에서 550 개의 이미지를 포함한다. 두 방법의 성능을 평가하기 위해 평균 제곱 오차 (MSE) 와 구조적 유사성 지수 (SSIM) 를 두 가지 지표로 추적한다. 눈 데이터셋에서 패치 방법은 평균 MSE 가 27,611 으로 U-Net 방법의 146,855 보다 낮고, 평균 SSIM 이 0.636 으로 U-Net 방법의 0.607 보다 높았다. 피부 데이터셋에서 패치 방법은 평균 MSE 가 3.768 으로 U-Net 방법의 4.032 보다 낮고, 평균 SSIM 이 0.824 으로 U-Net 방법의 0.783 보다 높았다. 이미지 품질 측면에서 더 우수한 성능을 보였음에도 불구하고, 예측 속도를 비교할 때 패치 방법은 U-Net 방법보다 느리며, 한 이미지를 예측하는 데 303 초가 소요되는 반면 U-Net 방법은 1 초 미만이다.
Two-photon excitation fluorescence (2PEF) allows imaging of tissue up to about one millimeter in thickness. Typically, reducing fluorescence excitation exposure reduces the quality of the image. However, using deep learning super resolution techniques, these low-resolution images can be converted to high-resolution images. This work explores improving human tissue imaging by applying deep learning to maximize image quality while reducing fluorescence excitation exposure. We analyze two methods: a method based on U-Net, and a patch-based regression method. Both methods are evaluated on a skin dataset and an eye dataset. The eye dataset includes 1200 paired high power and low power images of retinal organoids. The skin dataset contains multiple frames of each sample of human skin. High-resolution images were formed by averaging 70 frames for each sample and low-resolution images were formed by averaging the first 7 and 15 frames for each sample. The skin dataset includes 550 images for each of the resolution levels. We track two measures of performance for the two methods: mean squared error (MSE) and structural similarity index measure (SSIM). For the eye dataset, the patches method achieves an average MSE of 27,611 compared to 146,855 for the U-Net method, and an average SSIM of 0.636 compared to 0.607 for the U-Net method. For the skin dataset, the patches method achieves an average MSE of 3.768 compared to 4.032 for the U-Net method, and an average SSIM of 0.824 compared to 0.783 for the U-Net method. Despite better performance on image quality, the patches method is worse than the U-Net method when comparing the speed of prediction, taking 303 seconds to predict one image compared to less than one second for the U-Net method.