심층학습을 활용한 신생아 X 선 영상에서 다중 카테터의 자동 분류
Automatic classification of multiple catheters in neonatal radiographs with deep learning
Automatic classification of multiple catheters in neonatal radiographs with deep learning
@misc{henderson2020automatic,
title = {Automatic classification of multiple catheters in neonatal radiographs with deep learning},
author = {Robert D. E. Henderson and Xin Yi and Scott J. Adams and Paul Babyn},
year = {2020},
eprint = {2011.07394},
archivePrefix = {arXiv},
primaryClass = {cs.CV},
url = {https://arxiv.org/abs/2011.07394}
}
Henderson, R. D. E., Yi, X., Adams, S. J., & Babyn, P. (2020). Automatic classification of multiple catheters in neonatal radiographs with deep learning [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.07394
HENDERSON RDE, YI X, ADAMS SJ, et al. Automatic classification of multiple catheters in neonatal radiographs with deep learning[EB/OL]. (2020-11-14)[2026-11-29]. https://arxiv.org/abs/2011.07394.
초록
신생아 흉부 및 복부 X 선에서 다중 카테터 분류를 위한 심층 학습 알고리즘을 개발하고 평가한다. 777 장의 신생아 흉부 및 복부 X 선으로 구성된 데이터셋을 사용하여 훈련되었으며, 훈련 - 검증 - 테스트 비율은 각각 81%, 9%, 10%로 분할되었다. 우리는 ImageNet 에서 사전 훈련된 ResNet-50 (CNN) 을 사용하였다. 정답 라벨링은 각 이미지에 내호흡관 (ETT), 위음식관 (NGT), 그리고 우문동맥 및 정맥 카테터 (UAC, UVC) 의 존재 여부를 표시하는 것으로 제한되었다. 데이터셋에는 2 개 이상의 카테터가 포함된 561 장, 1 개만 포함된 167 장, 그리고 카테터가 없는 49 장의 이미지가 포함되었다. 성능은 정밀도 - 재현율 곡선 아래 면적에서 계산된 평균 정밀도 (AP) 로 측정되었다. 테스트 데이터에서 알고리즘은 NGT 에 대해 전체 AP 가 0.977 (95% 신뢰구간: 0.679-0.999), ETT 에 대해 0.989 (0.751-1.000), UAC 에 대해 0.979 (0.873-0.997), UVC 에 대해 0.937 (0.785-0.984) 를 달성하였다. 2 개 이상의 카테터가 포함된 58 장의 테스트 이미지 세트에서도 성능이 유사하게 나타났으며, NGT 에 대해 AP 가 0.975 (0.255-1.000), ETT 에 대해 0.997 (0.009-1.000), UAC 에 대해 0.981 (0.797-0.998), UVC 에 대해 0.937 (0.689-0.990) 로 측정되었다. 따라서 본 네트워크는 이 4 가지 카테터 유형의 동시 검출에서 강력한 성능을 발휘한다. 방사선사는 이러한 알고리즘을 X 선상의 카테터 보고 자동화를 위한 시간 절감 메커니즘으로 활용할 수 있다.
We develop and evaluate a deep learning algorithm to classify multiple catheters on neonatal chest and abdominal radiographs. A convolutional neural network (CNN) was trained using a dataset of 777 neonatal chest and abdominal radiographs, with a split of 81%-9%-10% for training-validation-testing, respectively. We employed ResNet-50 (a CNN), pre-trained on ImageNet. Ground truth labelling was limited to tagging each image to indicate the presence or absence of endotracheal tubes (ETTs), nasogastric tubes (NGTs), and umbilical arterial and venous catheters (UACs, UVCs). The data set included 561 images containing 2 or more catheters, 167 images with only one, and 49 with none. Performance was measured with average precision (AP), calculated from the area under the precision-recall curve. On our test data, the algorithm achieved an overall AP (95% confidence interval) of 0.977 (0.679-0.999) for NGTs, 0.989 (0.751-1.000) for ETTs, 0.979 (0.873-0.997) for UACs, and 0.937 (0.785-0.984) for UVCs. Performance was similar for the set of 58 test images consisting of 2 or more catheters, with an AP of 0.975 (0.255-1.000) for NGTs, 0.997 (0.009-1.000) for ETTs, 0.981 (0.797-0.998) for UACs, and 0.937 (0.689-0.990) for UVCs. Our network thus achieves strong performance in the simultaneous detection of these four catheter types. Radiologists may use such an algorithm as a time-saving mechanism to automate reporting of catheters on radiographs.