초록

번역 수정

심근 흉터 진단의 임상 표준인 후기 갈돌륨 강화 (LGE) 심장 자기공명영상 (CMR) 은 2D 영상에 비해 3D 등방성 LGE CMR 이 더 높은 커버리지와 해상도를 제공한다. 그러나 긴 스캔 시간과 대비 세척 현상 때문에 이미지 가속화가 필요하다. 최근 물리 지향 딥러닝 (PG-DL) 접근법이 개선된 가속 MRI 전략으로 등장했다. PG-DL 방법의 학습은 일반적으로 완전히 샘플링된 데이터를 참조로 하는 지도 학습 방식으로 수행되며, 이는 3D LGE CMR 에서 도전과제가 된다. 최근, 완전히 샘플링된 데이터 없이 PG-DL 기술을 학습할 수 있도록 하는 자기지도 학습 접근법이 제안되었다. 본 연구에서는 이 자기지도 학습 접근법을 3D 영상에 확장하고, 3D 볼륨의 작은 학습 데이터베이스 크기와 관련된 도전을 해결한다. 결과와 전향적 가속 3D LGE에 대한 독자 연구는 제안된 접근법이 6 배 가속화에서 임상적으로 사용되는 압축 센싱 접근법 (3 배 가속화) 을 능가함을 보여준다.