LUX 에서 새로운 전극 배경 완화 기법을 통해 저질량 암흑물질에 대한 감도 향상

Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique

Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique

arXiv:2011.09602 최초 게시 2020-11-19 v1 14 pages, 13 figures
이 논문 인용 ×
BibTeX
@misc{akerib2020improving,
  title = {Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique},
  author = {LUX Collaboration: D. S. Akerib and S. Alsum and H. M. Araújo and X. Bai and J. Balajthy and J. Bang and A. Baxter and E. P. Bernard and A. Bernstein and T. P. Biesiadzinski and E.M. Boulton and B. Boxer and P. Brás and S. Burdin and D. Byram and M. C. Carmona-Benitez and C. Chan and J. E. Cutter and L. de Viveiros and E. Druszkiewicz and A. Fan and S. Fiorucci and R. J. Gaitskell and C. Ghag and M. G. D. Gilchriese and C. Gwilliam and C. R. Hall and S. J. Haselschwardt and S. A. Hertel and D. P. Hogan and M. Horn and D. Q. Huang and C. M. Ignarra and R. G. Jacobsen and O. Jahangir and W. Ji and K. Kamdin and K. Kazkaz and D. Khaitan and E. V. Korolkova and S. Kravitz and V. A. Kudryavtsev and E. Leason and B. G. Lenardo and K. T. Lesko and J. Liao and J. Lin and A. Lindote and M. I. Lopes and A. Manalaysay and R. L. Mannino and N. Marangou and D. N. McKinsey and D.-M. Mei and J. A. Morad and A. St. J. Murphy and A. Naylor and C. Nehrkorn and H. N. Nelson and F. Neves and A. Nilima and K. C. Oliver-Mallory and K. J. Palladino and C.Rhyne and Q. Riffard and G. R. C. Rischbieter and P. Rossiter and S. Shaw and T. A. Shutt and C. Silva and M. Solmaz and V. N. Solovov and P. Sorensen and T. J. Sumner and N. Swanson and M. Szydagis and D. J. Taylor and R. Taylor and W. C. Taylor and B. P. Tennyson and P. A. Terman and D. R. Tiedt and W. H. To and L. Tvrznikova and U. Utku and A. Vacheret and A. Vaitkus and V. Velan and R. C. Webb and J. T. White and T. J. Whitis and M. S. Witherell and F. L. H. Wolfs and D. Woodward and X. Xiang and J. Xu and C. Zhang},
  year = {2020},
  eprint = {2011.09602},
  archivePrefix = {arXiv},
  primaryClass = {hep-ex},
  url = {https://arxiv.org/abs/2011.09602}
}
APA
Akerib, L. C. D. S., Alsum, S., Araújo, H. M., Bai, X., Balajthy, J., Bang, J., Baxter, A., Bernard, E. P., Bernstein, A., Biesiadzinski, T. P., Boulton, E., Boxer, B., Brás, P., Burdin, S., Byram, D., Carmona-Benitez, M. C., Chan, C., Cutter, J. E., Viveiros, L. D., & … Zhang, C. (2020). Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.09602
GB/T 7714
AKERIB LCDS, ALSUM S, ARAÚJO HM, et al. Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique[EB/OL]. (2020-11-19)[2026-11-29]. https://arxiv.org/abs/2011.09602.

초록

번역 수정

이 논문은 저질량 암흑 물질 (DM) 탐색을 위한 크세논 시간 투영 챔버의 감도 제한을 받는 전극 배경을 완화하기 위한 새로운 기법을 제시합니다. LUX 검출기에서 저질량 DM 상호작용의 신호는 활성 표적에서 몇 개의 크세논 원자를 이온화하고 거의 감지 가능한 스핀들광 신호를 생성하지 않는 매우 낮은 에너지 (keV) 산란으로 나타납니다. 이 영역에서는 이 검출기 클래스에서 오랫동안 관측되어 온 저에너지 전자 배경을 제거하기 위해 추가적인 주의가 필요합니다. 활성 표적의 상하부에 위치한 와이어 그리드 전극에서 발생하는 배경은 특히 치명적이므로, 이온화 펄스 형태를 기반으로 이러한 사건을 식별하고 제거하는 머신러닝 기법을 개발했습니다. 우리는 이 기법이 저질량 DM 상호작용의 포아송 한계를 2-7 배 개선할 수 있음을 보여주었으며, 개선 정도는 이온화 신호 크기에 크게 의존합니다. 우리는 LUX 의 2013 년 과학 운영 기간 동안의 5 톤 . 일 효과적 노출 데이터를 사용하여 질량이 m_chiin0.15-10 GeV 범위에 있는 저질량 DM 입자에 대해 강력한 한계를 설정했습니다. 이 머신러닝 기법은 LZ 와 XENONnT 와 같은 근미래 실험에 유용할 것으로 예상되며, 이러한 실험들은 발견을 가능하게 하는 엄격한 배경 제어를 통해 저질량 DM 탐색을 수행할 계획입니다.

#1 · 논문

토론

아직 댓글이 없습니다. 첫 댓글을 남겨 보세요.