간 및 신장 MRI 유도 고강도 초음파 집중 치료
MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney
MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney
@misc{senneville2020mriguided,
title = {MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney},
author = {Baudouin Denis de Senneville and Mario Ries and Wilbert Bartels and Chrit Moonen},
year = {2020},
eprint = {2011.10752},
archivePrefix = {arXiv},
primaryClass = {physics.med-ph},
url = {https://arxiv.org/abs/2011.10752}
}
Senneville, B. D. D., Ries, M., Bartels, W., & Moonen, C. (2020). MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.10752
SENNEVILLE BDD, RIES M, BARTELS W, et al. MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney[EB/OL]. (2020-11-21)[2026-11-29]. https://arxiv.org/abs/2011.10752.
초록
고강도 초점형 초음파 (HIFU) 는 비침습적으로 인체 내부 깊은 곳에 국소 온도 상승을 유도할 수 있다. MRI 를 이용한 절차 안내는 in situ 에서 표적 정의를 가능하게 한다. 또한, HIFU 절차 중 공간적 및 시간적 제어와 최종 병변 예측을 위해 열량 (thermal dose) 을 기반으로 지속적인 온도 매핑을 제공할 수 있다. 이동성 장기인 신장과 간에 대한 온도 매핑 및 HIFU 절차의 피드백 제어용 실시간 처리 방법은 여전히 도전과제이다. 본 논문에서는 이러한 장기들의 MRI 온도 매핑, HIFU 빔의 운동 보정, 간격막 HIFU 소닉레이션, 그리고 부피적 아블레이션과 피드백 제어 전략에 대한 최근 기술적 진전을 검토한다. 최근 임상 전 연구들은 각 새로운 방법의 실현 가능성을 입증하였다. 이러한 진전을 임상으로 전환하는 관점을 논의한다. 결론적으로 간과 신장에서의 아블레이션용 MRI 유도 HIFU 는 실현 가능해 보이나, 기술적으로 고도화된 방법들의 통합에 대한 추가 작업이 필요하다.
High Intensity Focused Ultrasound (HIFU) can be used to achieve a local temperature increase deep inside the human body in a non-invasive way. MRI guidance of the procedure allows in situ target definition. In addition, MRI can be used to provide continuous temperature mapping during HIFU for spatial and temporal control of the heating procedure and prediction of the final lesion based on the received thermal dose. Temperature mapping of mobile organs as kidney and liver is challenging, as well as real-time processing methods for feedback control of the HIFU procedure. In this paper, recent technological advances are reviewed in MR temperature mapping of these organs, in motion compensation of the HIFU beam, in intercostal HIFU sonication, and in volumetric ablation and feedback control strategies. Recent pre-clinical studies have demonstrated the feasibility of each of these novel methods. The perspectives to translate those advances into the clinic are addressed. It can be concluded that MR guided HIFU for ablation in liver and kidney appears feasible but requires further work on integration of technologically advanced methods.