심방 유입 도플러 분석을 위한 완전 자동화된 딥러닝 기법
Fully Automated Mitral Inflow Doppler Analysis Using Deep Learning
Fully Automated Mitral Inflow Doppler Analysis Using Deep Learning
@misc{elwazir2020fully,
title = {Fully Automated Mitral Inflow Doppler Analysis Using Deep Learning},
author = {Mohamed Y. Elwazir and Zeynettin Akkus and Didem Oguz and Jae K. Oh},
year = {2020},
eprint = {2011.12429},
archivePrefix = {arXiv},
primaryClass = {eess.IV},
url = {https://arxiv.org/abs/2011.12429}
}
Elwazir, M. Y., Akkus, Z., Oguz, D., & Oh, J. K. (2020). Fully Automated Mitral Inflow Doppler Analysis Using Deep Learning [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.12429
ELWAZIR MY, AKKUS Z, OGUZ D, et al. Fully Automated Mitral Inflow Doppler Analysis Using Deep Learning[EB/OL]. (2020-11-24)[2026-11-29]. https://arxiv.org/abs/2011.12429.
초록
심장초음파 (echo) 는 심장내과 의사의 진단 도구에서 필수적인 요소이다. 현재까지 거의 모든 심장초음파 파라미터는 숙련된 심장초음파 전문의의 시간 소모적인 수동 라벨링 및 측정을 필요로 하며, 초음파 이미지의 노이즈 및 아티팩트 특성에 의해 유의미한 변동성을 보인다. 예를 들어, 미트랄 유입 (MI) 도플러는 좌심실 (LV) 방추 기능을 평가하는 데 사용되며, 이는 다양한 심장 질환을 구별하는 데 임상적으로 매우 중요하다. 본 연구에서는 심전도 연구에서 획득한 MI 도플러 이미지를 라벨링하고, MI 도플러 신호의 포장을 감지하며, 포장에서 초기 및 후기 유입 (E 와 A 파) 유속과 E 파 감속 시간을 추출하는 완전 자동화 워크플로우를 제시한다. 우리는 140 명의 환자 5,544 장의 이미지로 24 가지 이미지 클래스 (MI 도플러 이미지 포함) 를 예측하기 위해 다양한 합성곱 신경망 (CNN) 모델을 훈련시켰으며, 40 명의 환자 1,737 장의 이미지에서 전체 정확도를 0.97 으로 달성했다. 자동화된 E 와 A 파 유속은 연동자 측정과 매우 높은 상관관계 (Pearson R 0.99 및 0.98) 와 Bland-Altman 일치 (평균 차이 0.06 및 0.05 m/s, 각각 SD 0.03) 를 보였다. 감속 시간 또한 좋은 (하지만 낮은) 상관관계 (Pearson R 0.82) 와 Bland-Altman 일치 (평균 차이: 34.1ms, SD: 30.9ms) 를 보였다. 이러한 결과는 도플러 심장초음파 측정 자동화의 가능성과 완전 자동화된 심장초음파 측정 패키지의 전망을 입증한다.
Echocardiography (echo) is an indispensable tool in a cardiologist's diagnostic armamentarium. To date, almost all echocardiographic parameters require time-consuming manual labeling and measurements by an experienced echocardiographer and exhibit significant variability, owing to the noisy and artifact-laden nature of echo images. For example, mitral inflow (MI) Doppler is used to assess left ventricular (LV) diastolic function, which is of paramount clinical importance to distinguish between different cardiac diseases. In the current work we present a fully automated workflow which leverages deep learning to a) label MI Doppler images acquired in an echo study, b) detect the envelope of MI Doppler signal, c) extract early and late filing (E and A wave) flow velocities and E-wave deceleration time from the envelope. We trained a variety of convolutional neural networks (CNN) models on 5544 images of 140 patients for predicting 24 image classes including MI Doppler images and obtained overall accuracy of 0.97 on 1737 images of 40 patients. Automated E and A wave velocity showed excellent correlation (Pearson R 0.99 and 0.98 respectively) and Bland Altman agreement (mean difference 0.06 and 0.05 m/s respectively and SD 0.03 for both) with the operator measurements. Deceleration time also showed good but lower correlation (Pearson R 0.82) and Bland-Altman agreement (mean difference: 34.1ms, SD: 30.9ms). These results demonstrate feasibility of Doppler echocardiography measurement automation and the promise of a fully automated echocardiography measurement package.