다중 반사면이 있는 프리폼 이미징 시스템 설계
Freeform imaging system design with multiple reflection surfaces
Freeform imaging system design with multiple reflection surfaces
@misc{nie2020freeform,
title = {Freeform imaging system design with multiple reflection surfaces},
author = {Yunfeng Nie and David R. Shafer and Heidi Ottevaere and Hugo Thienpont and Fabian Duerr},
year = {2020},
eprint = {2011.14802},
archivePrefix = {arXiv},
primaryClass = {physics.optics},
url = {https://arxiv.org/abs/2011.14802}
}
Nie, Y., Shafer, D. R., Ottevaere, H., Thienpont, H., & Duerr, F. (2020). Freeform imaging system design with multiple reflection surfaces [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.14802
NIE Y, SHAFER DR, OTTEVAERE H, et al. Freeform imaging system design with multiple reflection surfaces[EB/OL]. (2020-11-30)[2026-11-29]. https://arxiv.org/abs/2011.14802.
초록
반사형 이미징 시스템은 분광계, 망원경, 증강 및 가상현실 헤드셋, 리소그래피 플랫폼과 같은 광학 소자에서 중요한 역할을 한다. 반사 광학은 탁월한 스펙트럼 성능을 제공하며 전체 부피와 무게를 줄이는 데 활용될 수 있다. 지금까지 대부분의 반사 설계는 2 개 또는 3 개의 반사를 중심으로 이루어져 왔으나, 4 개 반사 프리폼 설계는 더 높은 빛 투과율 (빠른 F 수) 과 더 넓은 시야각 (FOV) 을 제공한다. 그러나 4 개 반사 프리폼 시스템에 대한 고급 광학 설계 전략은 문헌에서 드물게 보고되어 왔다. 이는 해결 공간의 복잡성 증가뿐만 아니라 추가 거울이 비용 효율적인 구현 (제조, 정렬 등) 을 방해하기 때문이다. 최근에는 거울의 위치와 기울기만 알면 프리폼 표면 계수를 직접 계산할 수 있는 새로운 설계 방법을 제안하였다. 결과적으로 이 방법은 기본 광학 설계 지식을 갖춘 비전문가도 몇 분 만에 '첫 시도부터 정답'인 프리폼 이미징 시스템을 계산할 수 있게 한다. 이는 대부분의 일반적인 프리폼 설계 프로세스가 상당한 경험, 직관 또는 추측을 필요로 하는 것과 대조된다. 먼저, 250mm 초점 거리, F/2.5, 8.5deg x 25.5deg의 넓은 직사각형 시야각을 가진 4 개 거울 고투과 망원경에 대해 제안된 방법의 효과성을 입증한다. 그 후, 2 개의 프리폼 거울과 1 개의 이중 반사 구면 거울로 구성된 3 개 거울 4 개 반사 이미징 시스템을 제안한다. 일반적인 3 개 거울 3 개 반사 이미저와 비교하여, 우리 새로운 다중 반사 시스템은 경제적인 구현의 전례 없는 가능성을 제공하면서도 전체 부피를 극적으로 줄인다.
Reflective imaging systems form an important part of photonic devices such as spectrometers, telescopes, augmented and virtual reality headsets or lithography platforms. Reflective optics provide unparalleled spectral performance and can be used to reduce overall volume and weight. So far, most reflective designs have focused on two or three reflections, while four-reflection freeform designs can deliver a higher light throughput (faster F-number) as well as a larger field-of-view (FOV). However, advanced optical design strategies for four-reflection freeform systems have been rarely reported in literature. This is due to the increased complexity in solution space but also the fact that additional mirrors hinder a cost-effective realization (manufacture, alignment, etc.). Recently, we have proposed a novel design method to directly calculate the freeform surface coefficients while merely knowing the mirror positions and tilts. Consequently, this method allows laymen with basic optical design knowledge to calculate 'first time right' freeform imaging systems in a matter of minutes. This contrasts with most common freeform design processes, which requires considerable experience, intuition or guesswork. Firstly, we demonstrate the effectiveness of the proposed method for a four-mirror high-throughput telescope with 250mm-focal-length, F/2.5 and a wide rectangular FOV of 8.5deg x 25.5deg. In a subsequent step, we propose an effective three-mirror but four-reflection imaging system, which consists of two freeform mirrors and one double-reflection spherical mirror. Compared with common three-mirror and three-reflection imagers, our novel multi-reflection system shows unprecedented possibilities for an economic implementation while drastically reducing the overall volume.