X-선 컴퓨터 단층촬영을 위한 심층 상호작용 노이즈 제거기 (DID)
Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
@misc{bai2020deep,
title = {Deep Interactive Denoiser (DID) for X-Ray Computed Tomography},
author = {Ti Bai and Biling Wang and Dan Nguyen and Bao Wang and Bin Dong and Wenxiang Cong and Mannudeep K. Kalra and Steve Jiang},
year = {2020},
eprint = {2011.14873},
archivePrefix = {arXiv},
primaryClass = {eess.IV},
url = {https://arxiv.org/abs/2011.14873}
}
Bai, T., Wang, B., Nguyen, D., Wang, B., Dong, B., Cong, W., Kalra, M. K., & Jiang, S. (2020). Deep Interactive Denoiser (DID) for X-Ray Computed Tomography [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2011.14873
BAI T, WANG B, NGUYEN D, et al. Deep Interactive Denoiser (DID) for X-Ray Computed Tomography[EB/OL]. (2020-11-30)[2026-11-29]. https://arxiv.org/abs/2011.14873.
초록
저선량 컴퓨터 단층촬영 (LDCT) 은 진단 영상 및 영상 유도 개입 모두에 바람직합니다. LDCT 의 품질을 개선하기 위해 노이즈 제거기 (denoiser) 가 널리 사용되고 있습니다. 딥러닝 (DL) 기반 노이즈 제거기는 최상위 성능을 보이며 주요 방법 중 하나가 되고 있습니다. 그러나 DL 기반 노이즈 제거기와 관련하여 두 가지 도전 과제가 존재합니다: 1) 학습된 모델은 일반적으로 서로 다른 노이즈 - 해상도 트레이드오프를 가진 서로 다른 이미지 후보를 생성하지 않으며, 이는 때때로 다른 임상 작업에 필요할 수 있습니다; 2) 테스트 이미지의 노이즈 수준이 학습 데이터셋의 노이즈 수준과 다르면 모델의 일반화 가능성이 문제가 될 수 있습니다. 이러한 두 가지 도전을 해결하기 위해 본 작업에서는 기존 모든 DL 기반 노이즈 제거기 위에 테스트 단계에서 경량 최적화 과정을 도입하여 서로 다른 노이즈 - 해상도 트레이드오프를 가진 다양한 임상 작업에 적합한 여러 이미지 후보를 실시간으로 생성합니다. 결과적으로, 우리의 방법은 사용자가 노이즈 제거기와 상호작용하여 다양한 이미지 후보를 효율적으로 검토하고 원하는 것을 빠르게 선택할 수 있게 하며, 이를 위해 딥 인터랙티브 노이즈 제거기 (DID) 로 명명되었습니다. 실험 결과는 DID 가 서로 다른 노이즈 - 해상도 트레이드오프를 가진 여러 이미지 후보를 제공할 수 있음을 보여주었으며, 다양한 네트워크 아키텍처뿐만 아니라 다양한 노이즈 수준을 가진 학습 및 테스트 데이터셋에 대해 뛰어난 일반화 가능성을 보여줍니다.
Low dose computed tomography (LDCT) is desirable for both diagnostic imaging and image guided interventions. Denoisers are openly used to improve the quality of LDCT. Deep learning (DL)-based denoisers have shown state-of-the-art performance and are becoming one of the mainstream methods. However, there exists two challenges regarding the DL-based denoisers: 1) a trained model typically does not generate different image candidates with different noise-resolution tradeoffs which sometimes are needed for different clinical tasks; 2) the model generalizability might be an issue when the noise level in the testing images is different from that in the training dataset. To address these two challenges, in this work, we introduce a lightweight optimization process at the testing phase on top of any existing DL-based denoisers to generate multiple image candidates with different noise-resolution tradeoffs suitable for different clinical tasks in real-time. Consequently, our method allows the users to interact with the denoiser to efficiently review various image candidates and quickly pick up the desired one, and thereby was termed as deep interactive denoiser (DID). Experimental results demonstrated that DID can deliver multiple image candidates with different noise-resolution tradeoffs, and shows great generalizability regarding various network architectures, as well as training and testing datasets with various noise levels.