멀시샷 인코딩 동시 다면 (MUSIUM) 을 이용한 내비게이션 프리 초단파 확산 영상
Navigator-Free Submillimeter Diffusion Imaging using Multishot-encoded Simultaneous Multi-slice (MUSIUM)
Navigator-Free Submillimeter Diffusion Imaging using Multishot-encoded Simultaneous Multi-slice (MUSIUM)
@misc{chang2020navigatorfree,
title = {Navigator-Free Submillimeter Diffusion Imaging using Multishot-encoded Simultaneous Multi-slice (MUSIUM)},
author = {Wei-Tang Chang and Khoi Minh Huynh and Pew-Thian Yap and Weili Lin},
year = {2020},
eprint = {2012.00664},
archivePrefix = {arXiv},
primaryClass = {physics.med-ph},
url = {https://arxiv.org/abs/2012.00664}
}
Chang, W.-T., Huynh, K. M., Yap, P.-T., & Lin, W. (2020). Navigator-Free Submillimeter Diffusion Imaging using Multishot-encoded Simultaneous Multi-slice (MUSIUM) [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2012.00664
CHANG WT, HUYNH KM, YAP PT, et al. Navigator-Free Submillimeter Diffusion Imaging using Multishot-encoded Simultaneous Multi-slice (MUSIUM)[EB/OL]. (2020-12-01)[2026-11-29]. https://arxiv.org/abs/2012.00664.
초록
미리미터 수준의 등방성 분산 자기공명영상 (dMRI) 을 달성하는 능력은 특히 피질과 같은 미세 구조를 연구하는 데 필수적입니다. 미리미터 dMRI 수행의 주요 과제는 본질적으로 낮은 신호 대 잡음비 (SNR) 입니다. 고해상도 dMRI 에서 낮은 SNR 을 완화할 수 있는 방법들, 즉 동시 다슬랩 (SMSlab) 과 일반화된 슬라이스 디터드 향상된 해상도 동시 다슬라이스 (gSlider-SMS) 가 제안되어 왔으나, 이러한 방법들은 한계가 있습니다. SMSlab 시퀀스는 슬랩 경계 아티팩트를 겪으며 위상 추정을 위해 추가적인 네비게이터가 필요합니다. 반면, gSlider 시퀀스는 상대적으로 높은 RF 파워와 피크 진폭을 필요로 하여 체내 흡수율 (SAR) 을 증가시키고 RF 여기 과정을 복잡하게 만듭니다. 본 연구에서는 3T MRI 스캐너에서 슬랩 경계 아티팩트 없이 향상된 SNR, 낮은 RF 파워 및 피크 진폭을 달성하는 네비게이터 없는 다샷 인코딩 동시 다슬라이스 (MUSIUM) 영상 접근법을 개발했습니다. 초고해상도 (0.86 mm 등방성 해상도), 전뇌 커버리지 및 약 12.5 분의 획득 시간을 달성하여 피질 및 백질 영역의 상세한 구조를 규명했습니다. 시뮬레이션 및 in vivo 결과 또한 MUSIUM 영상이 운동에 최소 영향을 받는다는 것을 보여줍니다. 종합적으로 MUSIUM 영상은 임상적으로 실현 가능한 스캔 시간 내에서 3T MRI 스캐너에서 미리미터 분산 영상을 달성할 수 있는 유망한 접근법입니다.
The ability to achieve submillimter isotropic resolution diffusion MR imaging (dMRI) is critically important to study fine-scale brain structures, particularly in the cortex. One of the major challenges in performing submillimeter dMRI is the inherently low signal-to-noise ratio (SNR). While approaches capable of mitigating the low SNR in high resolution dMRI have been proposed, namely simultaneous multi-slab (SMSlab) and generalized slice dithered enhanced resolution with simultaneous multislice (gSlider-SMS), limitations are associated with these approaches. The SMSlab sequences suffer from the slab boundary artifacts and require additional navigators for phase estimation. On the other hand, gSlider sequences require relatively high RF power and peak amplitude, which increase the SAR and complicate the RF excitation. In this work, we developed a navigator-free multishot-encoded simultaneous multi-slice (MUSIUM) imaging approach on a 3T MR scanner, achieving enhanced SNR, low RF power and peak amplitude, and being free from slab boundary artifacts. The dMRI with ultrahigh resolution (0.86 mm isotropic resolution), whole brain coverage and 12.5 minute acquisition time were achieved, revealing detailed structures at cortical and white matter areas. The simulated and in vivo results also demonstrated that the MUSIUM imaging was minimally affected by the motion. Taken together, the MUSIUM imaging is a promising approach to achieve submillimeter diffusion imaging on 3T MR scanners within clinically feasible scan time.