영상 유도 수술을 위한 증강 현실 등록 방법의 다중 센터 평가
Multicenter Assessment of Augmented Reality Registration Methods for Image-guided Interventions
Multicenter Assessment of Augmented Reality Registration Methods for Image-guided Interventions
@misc{li2020multicenter,
title = {Multicenter Assessment of Augmented Reality Registration Methods for Image-guided Interventions},
author = {Ningcheng Li and Jonathan Wakim and Yilun Koethe and Timothy Huber and Terence Gade and Stephen Hunt and Brian Park},
year = {2020},
eprint = {2012.02319},
archivePrefix = {arXiv},
primaryClass = {physics.med-ph},
url = {https://arxiv.org/abs/2012.02319}
}
Li, N., Wakim, J., Koethe, Y., Huber, T., Gade, T., Hunt, S., & Park, B. (2020). Multicenter Assessment of Augmented Reality Registration Methods for Image-guided Interventions [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2012.02319
LI N, WAKIM J, KOETHE Y, et al. Multicenter Assessment of Augmented Reality Registration Methods for Image-guided Interventions[EB/OL]. (2020-12-03)[2026-11-29]. https://arxiv.org/abs/2012.02319.
초록
목적: 증강현실 (AR) 을 활용하여 홀로그래픽 3 차원 (3D) 모델을 실제 환경에 정렬할 때 수동 및 자동 등록 시간과 정확도를 평가한다. 방법: 두 대학병원에서 임상 교육의 다양한 단계에 있는 18 명의 참여자가 HoloLens 2 증강현실 헤드셋을 사용하여 3D CT 가환모형 (phantom) 을 CT 그리드에 3 회 연속 등록했다. 등록 방법 (손 제스처, Xbox 컨트롤러, 자동 등록), 임상 경험 수준, 그리고 연속 시도 간 등록 시간과 정확도를 비교했다. 또한 등록 시간을 이전 HoloLens 1 데이터와 비교했다. 결과: 한 손 제스처, 두 손 제스처, Xbox 컨트롤러에 대한 평균 총 수동 등록 시간은 각각 27.7 초, 24.3 초, 72.8 초였으며, 평균 자동 등록 시간은 5.3 초였다 (ANOVA p<0.0001). 교수, 의과대학생, 조교수, 의대생 간 등록 시간에는 유의미한 차이가 없었다 (p>0.05). 손 제스처를 사용한 연속 시도 간 등록 시간에 유의미한 개선이 관찰되었다 (p<0.01). 이전 보고된 HoloLens 1 경험과 비교했을 때 손 제스처 등록 시간은 81.7% 빨라졌다 (p<0.05). 수동 등록 방법 간 등록 정확도에는 유의미한 차이가 없었으며, 한 손 제스처, 두 손 제스처, Xbox 컨트롤러에 따라 각각 5.9 mm, 9.5 mm, 8.6 mm 로 측정되었다 (p>0.05). 결론: HoloLens 2 에서 업데이트된 손 제스처 동작으로 수동 등록 시간이 HoloLens 1 대비 유의미하게 감소하여 자동 등록 시간 수준에 근접했으며, Xbox 컨트롤러 매개 등록을 능가했다. 이러한 결과는 HoloLens 2 의 절차적 의료 치료에 대한 광범위한 임상 통합을 장려할 것이다.
Purpose: To evaluate manual and automatic registration times as well as accuracy with augmented reality during alignment of a holographic 3-dimensional (3D) model onto the real-world environment. Method: 18 participants in various stages of clinical training across two academic centers registered a 3D CT phantom model onto a CT grid using the HoloLens 2 augmented reality headset 3 consecutive times. Registration times and accuracy were compared among different registration methods (hand gesture, Xbox controller, and automatic registration), levels of clinical experience, and consecutive attempts. Registration times were also compared with prior HoloLens 1 data. Results: Mean aggregate manual registration times were 27.7, 24.3, and 72.8 seconds for one-handed gesture, two-handed gesture, and Xbox controller, respectively; mean automatic registration time was 5.3s (ANOVA p<0.0001). No significant difference in registration times was found among attendings, residents and fellows, and medical students (p>0.05). Significant improvements in registration times were detected across consecutive attempts using hand gestures (p<0.01). Compared with previously reported HoloLens 1 experience, hand gesture registration times were 81.7% faster (p<0.05). Registration accuracies were not significantly different across manual registration methods, measuring at 5.9, 9.5, and 8.6 mm with one-handed gesture, two-handed gesture, and Xbox controller, respectively (p>0.05). Conclusions: Manual registration times decreased significantly with updated hand gesture maneuvers on HoloLens 2 versus HoloLens 1, approaching the registration times of automatic registration and outperforming Xbox controller mediated registration. These results will encourage wider clinical integration of HoloLens 2 in procedural medical care.