약물유전체학 연구에서 불균형 샘플 크기를 위한 수정된 최대 대비법
A modified maximum contrast method for unequal sample sizes in pharmacogenomic studies
A modified maximum contrast method for unequal sample sizes in pharmacogenomic studies
@misc{nagashima2020a,
title = {A modified maximum contrast method for unequal sample sizes in pharmacogenomic studies},
author = {Kengo Nagashima and Yasunori Sato and Chikuma Hamada},
year = {2020},
eprint = {2012.03475},
archivePrefix = {arXiv},
primaryClass = {stat.ME},
url = {https://arxiv.org/abs/2012.03475}
}
Nagashima, K., Sato, Y., & Hamada, C. (2020). A modified maximum contrast method for unequal sample sizes in pharmacogenomic studies [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2012.03475
NAGASHIMA K, SATO Y, HAMADA C. A modified maximum contrast method for unequal sample sizes in pharmacogenomic studies[EB/OL]. (2020-12-07)[2026-11-29]. https://arxiv.org/abs/2012.03475.
초록
약물유전체학 연구에서 생물학적 반응과 유전형 간의 연관성을 분석할 때, 얻은 데이터를 로그 변환한 후 Kruskal-Wallis 검정 또는 일원 분산 분석 (ANOVA) 을 사용하는 것이 일반적이다. 그러나 이러한 방법들은 예상치 못한 생물학적 반응 패턴을 탐지하는 데 효과적이지만, 예상되는 패턴을 탐지하는 검정력 (power) 은 감소한다. 이전에는 약물유전체학 연구에서 불균형 샘플 크기를 위해 최대 대비법 (maximum contrast method) 과 수정된 최대 대비법 (permuted modified maximum contrast method) 의 결합을 제안하였다. 그러나 수정된 최대 대비법 통계량의 분포는 잡음 파라미터 sigma^2, 즉 모집단 분산에 의존한다는 것을 발견하였다. 본 논문에서는 잡음 파라미터에 의존하지 않는 통계량을 갖는 수정된 최대 대비법을 제안한다. 또한 시뮬레이션 연구를 통해 이러한 방법들의 성능을 비교하였다. 시뮬레이션 결과는 수정된 최대 대비법이 가장 낮은 위양성률을 보였으며, 특정 조건에서 참 반응 패턴을 탐지하는 데 강력한 방법임을 시사한다. 또한 수정된 최대 대비법은 수정된 최대 대비법보다 더 빠르고 정확하다. 이러한 결과에 기반하여, 주어진 상황에서 적절한 방법을 선택할 수 있는 실용적인 규칙을 제시한다.
In pharmacogenomic studies, biomedical researchers commonly analyze the association between genotype and biological response by using the Kruskal-Wallis test or one-way analysis of variance (ANOVA) after logarithmic transformation of the obtained data. However, because these methods detect unexpected biological response patterns, the power for detecting the expected pattern is reduced. Previously, we proposed a combination of the maximum contrast method and the permuted modified maximum contrast method for unequal sample sizes in pharmacogenomic studies. However, we noted that the distribution of the permuted modified maximum contrast statistic depends on a nuisance parameter sigma^2, which is the population variance. In this paper, we propose a modified maximum contrast method with a statistic that does not depend on the nuisance parameter. Furthermore, we compare the performance of these methods via simulation studies. The simulation results showed that the modified maximum contrast method gave the lowest false-positive rate; therefore, this method is powerful for detecting the true response patterns in some conditions. Further, it is faster and more accurate than the permuted modified maximum contrast method. On the basis of these results, we suggest a rule of thumb to select the appropriate method in a given situation.