CHD-Bench: 상호작용적 검사를 통한 선천성 심장 질환 진단
CHD-Bench: Diagnosing Congenital Heart Disease through Interactive Examination
CHD-Bench: Diagnosing Congenital Heart Disease through Interactive Examination
@misc{p2026chdbench,
title = {CHD-Bench: Diagnosing Congenital Heart Disease through Interactive Examination},
author = {Gautham Krishnan P and Shrisharanyan Vasu and Aniketh Vijesh and Rajagopalan Rameshbabu and Harikrishnan Anil Maya and Sarin Xavier and Mahesh Kappanayil and Gilad Gressel},
year = {2026},
eprint = {2611.33775},
archivePrefix = {arXiv},
primaryClass = {cs.AI},
url = {https://arxiv.org/abs/2611.33775}
}
P, G. K., Vasu, S., Vijesh, A., Rameshbabu, R., Maya, H. A., Xavier, S., Kappanayil, M., & Gressel, G. (2026). CHD-Bench: Diagnosing Congenital Heart Disease through Interactive Examination [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2611.33775
P GK, VASU S, VIJESH A, et al. CHD-Bench: Diagnosing Congenital Heart Disease through Interactive Examination[EB/OL]. (2026-11-25)[2026-11-29]. https://arxiv.org/abs/2611.33775.
초록
선천성 심혈관 질환 (CHD) 진단은 심장 구조 간의 공간적 관계를 이해하는 것을 요구하며, 임상가는 CT 또는 심장 자기공명영상 (MRI) 슬라이드를 스크롤하거나 3D 재구성물을 회전시켜 이를 평가합니다. 자동화된 심장 분할 방법은 발전했으나, 부피 스캔에서 선천성 심장 결함을 식별하는 것은 여전히 해결되지 않은 과제입니다. 기존 두 가지 접근법은 정적 해부학적 이상에 국한된 손으로 만든 진단 규칙에 의존합니다. 우리는 38 가지 CHD 유형을 포괄하는 세 코호트에서 247 건의 CT 및 MRI 스캔을 대상으로 다중 레이블 작업과 평가 프로토콜을 정의한 첫 번째 상호작용형 CHD 진단 벤치마크인 CHD-Bench를 소개합니다. 또한, 22 가지 도구를 통해 3D Slicer 환경에서 VLM 을 실행하고 각 검사를 관리하며 결과 진단과 지원 뷰를 기록하는 오픈소스 소프트웨어인 CHD-Harness 를 제시합니다. 오프더 Shelf 의 의료용, 오픈 웨이트 및 클로즈드 웨이트 VLM 과 3D CNN 분류기, 그리고 기존 규칙 기반 결과를 비교 평가했습니다. CHD-Harness 와 함께 Gemini 4 Argon 은 세 코호트 모두에서 가장 높은 매크로 F1 점수 (0.63, 0.63, 0.43) 를 달성했습니다. 상호작용적 검사를 허용함으로써 정적 뷰 대비 매크로 F1 점수가 최대 20 포인트 증가했습니다. 이러한 결과는 CHD-Bench 와 CHD-Harness 를 상호작용형 CHD 진단용 VLM 개발 및 평가의 기초로 확립합니다.
Diagnosis of congenital heart disease (CHD) requires understanding the spatial relationships between cardiac structures, which clinicians assess by scrolling through CT or cardiac magnetic resonance imaging (MRI) slices and rotating 3D reconstructions. Although automated methods have advanced cardiac segmentation, identifying congenital heart defects from volumetric scans remains an open challenge. The two existing approaches rely on handcrafted diagnostic rules limited to static anatomical abnormalities. We introduce CHD-Bench, the first benchmark for interactive CHD diagnosis, defining a multi-label task and evaluation protocol over 247 CT and MRI scans from three cohorts covering 38 CHD types. We also present CHD-Harness, open-source software that runs a VLM in a 3D Slicer environment through 22 tools, manages each examination, and records the resulting diagnosis and supporting views. We evaluate off-the-shelf medical, open weight, and closed weight VLMs and compare them with a 3D CNN classifier and published rule-based results. Gemini 4 Argon with CHD-Harness achieves the highest macro F1 across all three cohorts (0.63, 0.63, and 0.43). Allowing for interactive examination raises its macro F1 by up to 20 points over static views. These results establish CHD-Bench and CHD-Harness as a foundation for developing and evaluating VLMs for interactive CHD diagnosis.