O modelo de perigo do estado latente, com aplicação à confiabilidade de turbinas eólicas
The latent state hazard model, with application to wind turbine reliability
The latent state hazard model, with application to wind turbine reliability
@misc{moghaddass2016the,
title = {The latent state hazard model, with application to wind turbine reliability},
author = {Ramin Moghaddass and Cynthia Rudin},
year = {2016},
eprint = {1601.08034},
archivePrefix = {arXiv},
primaryClass = {stat.AP},
url = {https://arxiv.org/abs/1601.08034}
}
Moghaddass, R., & Rudin, C. (2016). The latent state hazard model, with application to wind turbine reliability [Preprint]. arXiv. https://doi.org/10.48550/arXiv.1601.08034
MOGHADDASS R, RUDIN C. The latent state hazard model, with application to wind turbine reliability[EB/OL]. (2016-01-29)[2026-11-29]. https://arxiv.org/abs/1601.08034.
Resumo
Apresentamos um novo modelo para análise de confiabilidade capaz de distinguir o estado latente de vulnerabilidade interna do equipamento da vulnerabilidade causada por fontes externas temporárias. Considere um parque eólico em que cada turbina opera sob os efeitos externos de temperatura, velocidade e direção do vento, etc. A turbina pode falhar devido aos efeitos externos de um pico de temperatura. Se ela não falhar durante o pico de temperatura, ainda pode falhar devido à degradação interna, e o pico pode causar (ou ser indicativo de) essa degradação. A capacidade de identificar o estado latente subjacente pode ajudar a compreender melhor os efeitos das fontes externas e, assim, levar a uma tomada de decisão mais robusta. Apresentamos um estudo experimental utilizando medições de sensores SCADA de turbinas eólicas na Itália.
We present a new model for reliability analysis that is able to distinguish the latent internal vulnerability state of the equipment from the vulnerability caused by temporary external sources. Consider a wind farm where each turbine is running under the external effects of temperature, wind speed and direction, etc. The turbine might fail because of the external effects of a spike in temperature. If it does not fail during the temperature spike, it could still fail due to internal degradation, and the spike could cause (or be an indication of) this degradation. The ability to identify the underlying latent state can help better understand the effects of external sources and thus lead to more robust decision-making. We present an experimental study using SCADA sensor measurements from wind turbines in Italy.