Melhoria da sensibilidade em banda larga via feedback quântico coerente com simetria PT
Broadband sensitivity improvement via coherent quantum feedback with PT symmetry
Broadband sensitivity improvement via coherent quantum feedback with PT symmetry
@misc{li2020broadband,
title = {Broadband sensitivity improvement via coherent quantum feedback with PT symmetry},
author = {Xiang Li and Maxim Goryachev and Yiqiu Ma and Michael E. Tobar and Chunnong Zhao and Rana X Adhikari and Yanbei Chen},
year = {2020},
eprint = {2012.00836},
archivePrefix = {arXiv},
primaryClass = {quant-ph},
url = {https://arxiv.org/abs/2012.00836}
}
Li, X., Goryachev, M., Ma, Y., Tobar, M. E., Zhao, C., Adhikari, R. X., & Chen, Y. (2020). Broadband sensitivity improvement via coherent quantum feedback with PT symmetry [Preprint]. arXiv. https://doi.org/10.48550/arXiv.2012.00836
LI X, GORYACHEV M, MA Y, et al. Broadband sensitivity improvement via coherent quantum feedback with PT symmetry[EB/OL]. (2020-12-01)[2026-11-29]. https://arxiv.org/abs/2012.00836.
Resumo
Um detector ressonante convencional frequentemente enfrenta um compromisso entre largura de banda e sensibilidade de pico, que pode ser rastreada até o Limite de Cramér-Rao quântico. A dispersão anômala tem sido demonstrada para melhorar esse desempenho através de amplificação de sinal, tornando-o mais robusto contra a decoerência, embora isso leve a instabilidades. Propomos um amplificador quântico estável aplicável a sistemas lineares operando nos limites fundamentais de detecção, habilitado pela amplificação paramétrica não degenerada de dois modos. No limiar, um dos modos do amplificador forma um sistema simétrico PT do modo original do detector. Melhorias na sensibilidade são demonstradas para detectores de ondas gravitacionais de interferometria a laser e detectores de axions em cavidades de micro-ondas.
A conventional resonant detector is often subject to a trade-off between bandwidth and peak sensitivity that can be traced back to quantum Cramer-Rao Bound. Anomalous dispersion has been shown to improve it by signal amplification and is thus more robust against decoherence, while it leads to instabilities. We propose a stable quantum amplifier applicable to linear systems operating at the fundamental detection limits, enabled by two-mode non-degenerate parametric amplification. At threshold, one mode of the amplifier forms a PT-symmetric system of original detector mode. Sensitivity improvements are shown for laser-interferometric gravitational-wave detectors and microwave cavity axion detectors.